SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-188189"
 

Sökning: id:"swepub:oai:DiVA.org:umu-188189" > Effects of Position...

Effects of Positioning of Multi-Sensor Devices on Occupancy and Indoor Environmental Monitoring in Single-Occupant Offices

Azizi, Shoaib (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy efficiency
Rabiee, Ramtin (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy efficiency
Nair, Gireesh (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy Efficiency
visa fler...
Olofsson, Thomas, 1968- (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy efficiency
visa färre...
 (creator_code:org_t)
2021-10-02
2021
Engelska.
Ingår i: Energies. - : MDPI. - 1996-1073. ; 14:19
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The advancements in sensor and communication technologies drive the rapid developments in the applications of occupancy and indoor environmental monitoring in buildings. Currently, the installation standards for sensors are scarce and the recommendations for sensor positionings are very general. However, inadequate sensor positioning might diminish the reliability of sensor data, which could have serious impacts on the intended applications such as the performance of demand-controlled HVAC systems and their energy use. Thus, there is a need to understand how sensor positioning may affect the sensor data, specifically when using multi-sensor devices in which several sensors are being bundled together. This study is based on the data collected from 18 multi-sensor devices installed in three single-occupant offices (six sensors in each office). Each multi-sensor device included sensors to measure passive infrared (PIR) radiation, temperature, CO2, humidity, and illuminance. The results show that the positions of PIR and CO2 sensors significantly affect the reliability of occupancy detection. The typical approach of positioning the sensors on the ceiling, in the middle of offices, may lead to relatively unreliable data. In this case, the PIR sensor in that position has only 60% accuracy of presence detection. Installing the sensors under office desks could increase the accuracy of presence detection to 84%. These two sensor positions are highlighted in sensor fusion analysis as they could reach the highest accuracy compared to other pairs of PIR sensors. Moreover, sensor positioning can affect various indoor environmental parameters, especially temperature and illuminance measurements.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

data reliability
sensor placement
IoT
sensor accuracy
PIR sensors
sensor fusion

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Energies (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Azizi, Shoaib
Rabiee, Ramtin
Nair, Gireesh
Olofsson, Thomas ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
Energies
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy