Stäng  
  • Background: Human movement is generated by activating motor units (MUs), i.e., the smallest structures that can be voluntarily controlled. Recent findings have shown imaging of voluntarily activated MUs using ultrafast ultrasound based on displacement velocity images and a decomposition algorithm. Given this, estimates of trains of twitches (unfused tetanic signals) evoked by the neural discharges (spikes) of spinal motor neurons are provided. Based on these signals, a band-pass filter method (BPM) has been used to estimate its spike train. In addition, an improved spike estimation method consisting of a continuous Haar wavelet transform method (HWM) has been suggested. However, the parameters of the two methods have not been optimized, and their performance has not been compared rigorously.Method: HWM and BPM were optimized using simulations. Their performance was evaluated based on simulations and two experimental datasets with 21 unfused tetanic contractions considering their rate of agreement, spike offset, and spike offset variability with respect to the simulated or experimental spikes.Results: A range of parameter sets that resulted in the highest possible agreement with simulated spikes was provided. Both methods highly agreed with simulated and experimental spikes, but HWM was a better spike estimation method than BPM because it had a higher agreement, less bias, and less variation (p < 0.001).Conclusions: The optimized HWM will be an important contributor to further developing the identification and analysis of MUs using imaging, providing indirect access to the neural drive of the spinal cord to the muscle by the unfused tetanic signals.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Publikations- och innehållstyp

vet (ämneskategori)
ovr (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Rohlén, Robin
Antfolk, Christi ...
Grönlund, Christ ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy