SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-200460"
 

Sökning: id:"swepub:oai:DiVA.org:umu-200460" > Interframe Echo Int...

Interframe Echo Intensity Variation of Subregions and Whole Plaque in Two-Dimensional Carotid Ultrasonography : Simulations and in Vivo Observations

Rohlén, Robin (författare)
Umeå universitet,Radiofysik
Jiang, Biao (författare)
Umeå universitet,Radiofysik
Nyman, Emma (författare)
Umeå universitet,Avdelningen för medicin
visa fler...
Wester, Per, 1959- (författare)
Umeå universitet,Avdelningen för medicin
Näslund, Ulf (författare)
Umeå universitet,Avdelningen för medicin
Grönlund, Christer (författare)
Umeå universitet,Radiofysik
visa färre...
 (creator_code:org_t)
2022-10-20
2023
Engelska.
Ingår i: Journal of ultrasound in medicine. - : John Wiley & Sons. - 0278-4297 .- 1550-9613. ; 42:5, s. 1033-1046
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: The risk of cardiovascular disease is associated with the echo intensity of carotid plaques in ultrasound images and their cardiac cycle-induced intensity variations. In this study, we aimed to 1) explore the underlying origin of echo intensity variations by using simulations and 2) evaluate the association between the two-dimensional (2D) spatial distribution of these echo intensity variations and plaque vulnerability.Methods: First, we analyzed how out-of-plane motion and compression of simulated scattering spheres of different sizes affect the ultrasound echo intensity. Next, we propose a method to analyze the features of the 2D spatial distribution of interframe plaque echo intensity in carotid ultrasound image sequences and explore their associations with plaque vulnerability in experimental data.Results: The simulations showed that the magnitude of echo intensity changes was similar for both the out-of-plane motion and compression, but for scattering objects smaller than 1 mm radius, the out-of-plane motion dominated. In experimental data, maps of the 2D spatial distribution of the echo intensity variations had a low correlation with standard B-mode echo intensity distribution, indicating complementary information on plaque tissue composition. In addition, we found the existence of ∼1 mm diameter subregions with pronounced echo intensity variations associated with plaque vulnerability.Conclusions: The results indicate that out-of-plane motion contributes to intra-plaque regions of high echo intensity variation. The 2D echo intensity variation maps may provide complementary information for assessing plaque composition and vulnerability. Further studies are needed to verify this method's role in identifying vulnerable plaques and predicting cardiovascular disease risk.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Rohlén, Robin
Jiang, Biao
Nyman, Emma
Wester, Per, 195 ...
Näslund, Ulf
Grönlund, Christ ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Artiklar i publikationen
Journal of ultra ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy