SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-202433"
 

Sökning: id:"swepub:oai:DiVA.org:umu-202433" > Accuracy, precision...

Accuracy, precision, and safety of stereotactic, frame-based, intraoperative MRI-guided and MRI-verified deep brain stimulation in 650 consecutive procedures

Rajabian, Ali (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom; Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, Queen Square, London, United Kingdom
Vinke, Saman (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Candelario-Mckeown, Joseph (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
visa fler...
Milabo, Catherine (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Salazar, Maricel (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Nizam, Abdul Karim (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Salloum, Nadia (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Hyam, Jonathan (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom; Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, Queen Square, London, United Kingdom
Akram, Harith (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom; Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, Queen Square, London, United Kingdom
Joyce, Eileen (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Foltynie, Thomas (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Limousin, Patricia (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Hariz, Marwan (författare)
Umeå universitet,Neurovetenskaper,Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom
Zrinzo, Ludvic (författare)
Department of Clinical and Movement Neurosciences, Functional Neurosurgery Unit, University College London, Institute of Neurology, Queen Square, London, United Kingdom; Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, Queen Square, London, United Kingdom
visa färre...
 (creator_code:org_t)
Journal of Neurosurgery Publishing Group (JNSPG), 2023
2023
Engelska.
Ingår i: Journal of Neurosurgery. - : Journal of Neurosurgery Publishing Group (JNSPG). - 0022-3085 .- 1933-0693. ; 138, s. 1702-1711
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: Suboptimal lead placement is one of the most common indications for deep brain stimulation (DBS) revision procedures. Confirming lead placement in relation to the visible anatomical target with dedicated stereotactic imaging before terminating the procedure can mitigate this risk. In this study, the authors examined the accuracy, precision, and safety of intraoperative MRI (iMRI) to both guide and verify lead placement during frame-based stereotactic surgery.METHODS: A retrospective analysis of 650 consecutive DBS procedures for targeting accuracy, precision, and perioperative complications was performed. Frame-based lead placement took place in an operating room equipped with an MRI machine using stereotactic images to verify lead placement before removing the stereotactic frame. Immediate lead relocation was performed when necessary. Systematic analysis of the targeting error was calculated.RESULTS: Verification of 1201 DBS leads with stereotactic MRI was performed in 643 procedures and with stereotactic CT in 7. The mean ± SD of the final targeting error was 0.9 ± 0.3 mm (range 0.1-2.3 mm). Anatomically acceptable lead placement was achieved with a single brain pass for 97% (n = 1164) of leads; immediate intraoperative relocation was performed in 37 leads (3%) to obtain satisfactory anatomical placement. General anesthesia was used in 91% (n = 593) of the procedures. Hemorrhage was noted after 4 procedures (0.6%); 3 patients (0.4% of procedures) presented with transient neurological symptoms, and 1 experienced delayed cognitive decline. Two bleeds coincided with immediate relocation (2 of 37 leads, 5.4%), which contrasts with hemorrhage in 2 (0.2%) of 1164 leads implanted on the first pass (p = 0.0058). Three patients had transient seizures in the postoperative period. The seizures coincided with hemorrhage in 2 of these patients and with immediate lead relocation in the other. There were 21 infections (3.2% of procedures, 1.5% in 3 months) leading to hardware removal. Delayed (> 3 months) retargeting of 6 leads (0.5%) in 4 patients (0.6% of procedures) was performed because of suboptimal stimulation benefit. There were no MRI-related complications, no permanent motor deficits, and no deaths.CONCLUSIONS: To the authors' knowledge, this is the largest series reporting the use of iMRI to guide and verify lead location during DBS surgery. It demonstrates a high level of accuracy, precision, and safety. Significantly higher hemorrhage was encountered when multiple brain passes were required for lead implantation, although none led to permanent deficit. Meticulous audit and calibration can improve precision and maximize safety.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Nyckelord

functional neurosurgery
intraoperative MRI-guided and MRI-verified deep brain stimulation
stereotactic accuracy and precision
neurokirurgi
Neurosurgery

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy