SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-214256"
 

Sökning: id:"swepub:oai:DiVA.org:umu-214256" > Self-calibrated NIC...

Self-calibrated NICE-OHMS based on an asymmetric signal : theoretical analysis and experimental validation

Zhou, Yueting (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
Zhang, Zihao (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
Li, Yanke (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
visa fler...
Zhao, Gang (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
Zhou, Xiaobin (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
Zhang, Bofeng (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
Jiao, Kang (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
Yan, Xiaojuan (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
Li, Chuanliang (författare)
School of Applied Science, Taiyuan University of Science and Technology, Taiyuan, China
Axner, Ove (författare)
Umeå universitet,Institutionen för fysik
Ma, Weiguang (författare)
State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
visa färre...
 (creator_code:org_t)
Optical Society of America, 2023
2023
Engelska.
Ingår i: Optics Express. - : Optical Society of America. - 1094-4087. ; 31:17, s. 27830-27842
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • As an ultra-sensitive detection technique, the noise-immune cavity enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) technique has great potential for assessment of the concentration of trace gases. To determine gas concentrations at the ppt or lower level with high accuracy, it is desirable that the technique exhibits self-calibration (or calibration-free) capabilities. Although being sensitive, NICE-OHMS has so far not demonstrated any such ability. To remedy this, this paper provides a self-calibrated realization of NICE-OHMS that is based on a switching of the feedback target of the DeVoe-Brewer (DVB) locking procedure from the modulation frequency of the frequency modulation spectroscopy (FMS) to the cavity length, which creates an asymmetrical signal whose form and size can be used to unambiguously assess the gas concentration. A comprehensive theoretical model for self-calibrated NICE-OHMS is established by analyzing the shift of cavity modes caused by intracavity absorption, demonstrating that gas absorption information can be encoded in both the laser frequency and the NICE-OHMS signal. To experimentally verify the methodology, we measure a series of dispersion signals under different levels of absorbance using a built experimental setup. An instrument factor and the partial pressure are obtained by fitting the measured signal through theoretical expressions. Our results demonstrate that fitted values are more accurate for higher partial pressures than for lower. To improve on the accuracy at low partial pressures, it is shown that the instrument factor obtained by fitting the signal at large partial pressures (in this case, above 7.8 µTorr) can be set to a fixed value for all fits. By this, the partial pressures can be assessed with a relative error below 0.65%. This technique has the potential to enable calibration-free ultra-sensitive gas detection.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy