Static blood-flow control during cardiopulmonary bypass is a compromise of oxygen delivery

Svenmarker, Staffan (författare)
Umeå universitet,Anestesiologi och intensivvård
Häggmark, Sören (författare)
Umeå universitet,Anestesiologi och intensivvård
Hultin, Magnus (författare)
Umeå universitet,Anestesiologi och intensivvård
visa fler...
Holmgren, Anders (författare)
Umeå universitet,Kirurgi
visa färre...
 (creator_code:org_t)
Oxford University Press (OUP), 2009
2009
Engelska.
Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940 .- 1873-734X. ; 37:1, s. 218-222
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Blood-flow control during cardiopulmonary bypass (CPB) is by tradition based on the patient's body surface area. Emergence of new techniques enables dynamic blood-flow control based on online measurement of venous oxygen saturation and oxygen consumption. Present investigation aimed to compare static versus dynamic blood-flow control with respect to use of oxygen and effects upon organ function. Methods: In this study, 100 coronary-artery-bypass surgical patients were prospectively randomised to static or dynamic hypothermic blood-flow control during CPB. In the static group, pump flow was set to 2.4 (litres per minute) times the patient's body surface area (m(2)) throughout the procedure. Pump flow in the dynamic group was varied according to the reading of the venous oxygen saturation and maintained at >75%. CPB-specific information was collected online. Blood samples were collected for analysis of haemoglobin, lactate, amylase, creatinine and C-reactive protein: pre-CPB, at weaning from CPB and on day 1 postoperatively. Results: Randomisation formed two uniform groups. Choice of static or dynamic blood-flow control during CPB had no significant effects on organ function as judged by lactate, amylase or creatinine levels. On increasing oxygen demand, oxygen balance was maintained by increasing venous oxygen extraction rates in the static flow mode and by increasing the pump flow rate in the dynamic group. Conclusions: Independent of the blood-flow control mode, oxygen balance remained preserved. However, the dynamic mode provided higher oxygen delivery, which may increase margins of safety and protection of organ function.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Svenmarker, Staf ...
Häggmark, Sören
Hultin, Magnus
Holmgren, Anders
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
European Journal ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy