SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-31431"
 

Sökning: id:"swepub:oai:DiVA.org:umu-31431" > Assessment of myoca...

Assessment of myocardium at risk in pigs with single photon emission computed tomography and computerized vectorcardiography during transient coronary occlusion

Jensen, Steen (författare)
Umeå universitet,Kardiologi
Karp, Kjell (författare)
Umeå universitet,Klinisk fysiologi
Häggmark, Sören (författare)
Umeå universitet,Anestesiologi och intensivvård
visa fler...
Johansson, Göran (författare)
Umeå universitet,Anestesiologi och intensivvård
Näslund, Ulf (författare)
Umeå universitet,Kardiologi
visa färre...
 (creator_code:org_t)
2000
2000
Engelska.
Ingår i: Scand Cardiovasc J. ; 34:2, s. 142-8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Since myocardium at risk (MAR) is the major prognosticator of final infarct size and outcome in patients with acute myocardial infarction, it is highly desirable to estimate the size of the acutely ischemic myocardium, that is the MAR, in these patients. We assessed MAR size by Tc-99m-sestamibi-SPECT and computerized vectorcardiography using autoradiography as reference method. Transient myocardial ischemia was achieved in 12 pigs by coronary artery occlusion with PTCA catheters. During the procedure, computerized vectorcardiography was continuously recorded. After injection of Tc-99m-sestamibi and gadolinium-153-labelled microspheres, MAR size was estimated by SPECT and post-mortem autoradiography. Different cut-off levels (50-70%) were compared with respect to MAR-SPECT. Tc-99m-sestamibi-SPECT showed a good correlation with autoradiography (r = 0.94). Computerized vectorcardiography showed a good correlation with autoradiography as well as with Tc-99m-sestamibi-SPECT (STC-VM: r = 0.75 and 0.80, respectively, ST-VM: 0.75 and 0.87, respectively). It was found that 1) MAR assessed by Tc-99m-sestamibi-SPECT correlates closely with the autoradiographic reference; 2) a lower cut-off point of 60% of maximum uptake for MAR by Tc-99m-sestamibi-SPECT gives the closest correlation with the autoradiographic reference; and 3) ST-VM and STC-VM correlate well with MAR assessed by Tc-99m-sestamibi-SPECT and autoradiography.

Nyckelord

Animals
Coronary Disease/*radionuclide imaging
Female
Risk Factors
Swine
*Tomography
Emission-Computed
Single-Photon
*Vectorcardiography

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jensen, Steen
Karp, Kjell
Häggmark, Sören
Johansson, Göran
Näslund, Ulf
Artiklar i publikationen
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy