SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-34783"
 

Sökning: id:"swepub:oai:DiVA.org:umu-34783" > Field validation of...

Field validation of the Ogawa diffusive sampler for NO(2) and NO(x) in a cold climate

Hagenbjörk-Gustafsson, Annika (författare)
Umeå universitet,Yrkes- och miljömedicin,Arcum
Tornevi, Andreas (författare)
Umeå universitet,Yrkes- och miljömedicin
Forsberg, Bertil (författare)
Umeå universitet,Yrkes- och miljömedicin,Arcum
visa fler...
Eriksson, Kåre (författare)
Umeå universitet,Yrkes- och miljömedicin,Arcum
visa färre...
 (creator_code:org_t)
Royal Society of Chemistry, 2010
2010
Engelska.
Ingår i: Journal of Environmental Monitoring. - : Royal Society of Chemistry. - 1464-0325 .- 1464-0333. ; 12:6, s. 1315-24
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A small-scale field trial in Umeå, Sweden with Ogawa samplers and a chemiluminescence instrument indicated that the NO(2) concentration was underestimated with respect to the reference monitor, if calculated according to the manufacturer's Ogawa sampling protocol. By co-locating Ogawa samplers and reference monitors at six sites in two Swedish cities, uptake rates were determined for NO(2) and NO(x) better applicable to the Swedish conditions and climate. The concentrations of NO(2) and NO(x) calculated according to the instruction manual of the sampler and using the field-determined uptake rates were compared with values derived from chemiluminescence monitors for each week over which samples were taken. When calculated according to the manufacturer's suggested protocol, the Ogawa sampler underestimated the NO(2) concentrations by 9.1% on average for all samples (N = 53), with respect to the reference monitor. In contrast, NO(x) concentrations were overestimated by a mean value of 15% for all samples (N = 45). By using the field determined uptake rates for the calculation of NO(2) and NO(x) a better estimation of the concentrations was obtained. The ratio between concentrations determined with the Ogawa samplers and chemiluminescence monitors was then 1.02 for all measurements of NO(2) and 1.00 for NO(x). Precision, expressed as the mean coefficient of variation, was 6.4% for six, 6-replicate measurements of NO(2) and 3.7% for five, 6-replicate measurements of NO(x).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hagenbjörk-Gusta ...
Tornevi, Andreas
Forsberg, Bertil
Eriksson, Kåre
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Arbetsmedicin oc ...
Artiklar i publikationen
Journal of Envir ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy