SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-36274"
 

Sökning: id:"swepub:oai:DiVA.org:umu-36274" > Test-retest reliabi...

Test-retest reliability of step counts with the ActivPAL™ device in common daily activities.

Dahlgren, Gunilla (författare)
Umeå universitet,Institutionen för samhällsmedicin och rehabilitering
Carlsson, Daniel (författare)
Umeå universitet,Sjukgymnastik
Moorhead, Anne (författare)
Health and Rehabilitation Sciences Research Institute, School of Health Sciences, University of Ulster, Co. Antrim, Northern Ireland, United Kingdom
visa fler...
Häger-Ross, Charlotte (författare)
Umeå universitet,Sjukgymnastik
McDonough, Suzanne M (författare)
Health and Rehabilitation Sciences Research Institute, School of Health Sciences, University of Ulster, Co. Antrim, Northern Ireland, United Kingdom
visa färre...
 (creator_code:org_t)
Elsevier, 2010
2010
Engelska.
Ingår i: Gait & Posture. - : Elsevier. - 0966-6362 .- 1879-2219. ; 32:3, s. 386-90
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The ActivPAL device is a well-established physical activity monitor for assessment of physical activity. AIM: To investigate test-retest reliability of step counts and establish minimal detectable changes (MDC) in step count to account for intra device error over time in various physical activities. METHODS: Healthy participants (n=24, age range, 19-28 years) performed activities on two occasions, 1 week apart, in a laboratory setting; self-paced floor walking, treadmill walking at three different speeds (3.2 km/h, 4.5 km/h and 4.5 km/h with incline), treadmill jogging (8.0 km/h), stair walking and cycling on an exercise bike at three speeds (45 rpm, 60 rpm and 75 rpm). Relative reliability was calculated using intraclass correlation coefficient (ICC) and Spearman correlation. Absolute reliability was assessed using standard error of measurement (SEM) and coefficient of repeatability (CR). RESULTS: The ActivPAL showed high to very high relative reliability for treadmill walking at all speeds and stair walking, while self-paced normal floor walking showed moderate reliability. The absolute reliability was the best for treadmill walking activities, slightly increased for self-paced walking, followed by stair walking and jogging. The use of activity monitors during cycling has been questioned and our results confirm a low absolute and relative reliability. MDC values varied according to the type of activity e.g. treadmill walking 4.5 km/h (10 steps), walking on the floor (45 steps). Data loss in this study (10-13%) was higher than previously reported. CONCLUSIONS: The ActivPAL is reliable for treadmill walking, jogging and self-paced walking. MCD varies according to the activity and should be considered when establishing true change over time.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)

Nyckelord

Accelerometer; Physical activity; Reliability; ActivPAL
sjukgymnastik
Physiotherapy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy