SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-40235"
 

Sökning: id:"swepub:oai:DiVA.org:umu-40235" > 99mTc-diethylenetri...

99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach

Gref, Margareta, 1950- (författare)
Umeå universitet,Klinisk fysiologi
Karp, Kjell (författare)
Umeå universitet,Klinisk fysiologi
 (creator_code:org_t)
2009
2009
Engelska.
Ingår i: Nuclear medicine communications. - 0143-3636 .- 1473-5628. ; 30:3, s. 202-205
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: The single-sample 99mTc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) ≥30 ml/min. The purpose of this study was to test a new 99mTc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Methods: Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both 51Cr-EDTA and 99mTc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula Equation (Uncited)Image Tools C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6×body surface area-28.2. Results: The mean difference between reference and 99mTc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for 99mTc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for 51Cr-EDTA as reference clearance. Conclusion: In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of 99mTc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

Nyckelord

glomerular filtration rate
renal function
single sample
24 h sample
99mTc-diethylenetriamine penta-acetate clearance

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gref, Margareta, ...
Karp, Kjell
Artiklar i publikationen
Nuclear medicine ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy