SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-55477"
 

Sökning: id:"swepub:oai:DiVA.org:umu-55477" > Measuring pulsatile...

Measuring pulsatile flow in cerebral arteries using 4D phase-contrast magnetic resonance imaging

Wåhlin, Anders (författare)
Umeå universitet,Radiofysik
Ambarki, Khalid (författare)
Umeå universitet,Radiofysik,Centrum för medicinsk teknik och fysik (CMTF)
Birgander, Richard (författare)
Umeå universitet,Diagnostisk radiologi
visa fler...
Wieben, O (författare)
Johnson, KM (författare)
Malm, Jan (författare)
Umeå universitet,Klinisk neurovetenskap
Eklund, Anders (författare)
Umeå universitet,Radiofysik,Centrum för medicinsk teknik och fysik (CMTF)
visa färre...
 (creator_code:org_t)
2013
2013
Engelska.
Ingår i: American Journal of Neuroradiology. - 0195-6108 .- 1936-959X. ; 34:9, s. 1740-1745
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • BACKGROUND AND PURPOSE: 4D PCMRI can be used to quantify pulsatile hemodynamics in multiple cerebral arteries. The aim of this study was to compare 4D PCMRI and 2D PCMRI for assessments of pulsatile hemodynamics in major cerebral arteries. MATERIALS AND METHODS: We scanned the internal carotid artery, the anterior cerebral artery, the basilar artery, and the middle cerebral artery in 10 subjects with a single 4D and multiple 2D PCMRI acquisitions by use of a 3T system and a 32-channel head coil. We assessed the agreement regarding net flow and the volume of arterial pulsatility (V) for all vessels. RESULTS: 2D and 4D PCMRI produced highly correlated results, with r = 0.86 and r = 0.95 for V and net flow, respectively (n = 69 vessels). These values increased to r = 0.93 and r = 0.97, respectively, during investigation of a subset of measurements with <5% variation in heart rate between the 4D and 2D acquisition (n = 31 vessels). Significant differences were found for ICA and MCA net flow (P = .004 and P < .001, respectively) and MCA V (P = .006). However, these differences were attenuated and no longer significant when the subset with stable heart rate (n = 31 vessels) was analyzed. CONCLUSIONS: 4D PCMRI provides a powerful methodology to measure pulsatility of the larger cerebral arteries from a single acquisition. A large part of differences between measurements was attributed to physiologic variations. The results were consistent with 2D PCMRI.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Publikations- och innehållstyp

vet (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy