SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-78438"
 

Sökning: id:"swepub:oai:DiVA.org:umu-78438" > Bone contrast optim...

Bone contrast optimization in magnetic resonance imaging using experimental design of ultra-short echo-time parameters

Lindström, Anton (författare)
Umeå universitet,Radiofysik
Andersson, C. David (författare)
Umeå universitet,Kemiska institutionen
Johansson, Adam (författare)
Umeå universitet,Radiofysik
visa fler...
Karlsson, Mikael (författare)
Umeå universitet,Radiofysik
Nyholm, Tufve (författare)
Umeå universitet,Radiofysik,Onkologi
visa färre...
 (creator_code:org_t)
Elsevier Science, 2013
2013
Engelska.
Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier Science. - 0169-7439 .- 1873-3239. ; 125, s. 33-39
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • For the purpose of improved planning and treatment by radiation of tumours, we present work exploring the effect of controllable ultra-short echo-time (UTE) sequence settings on the bone contrast in magnetic resonance (MR) imaging, using design of experiments (DoE). Images were collected using UTE sequences from MR imaging and from standard computed tomography (CT). CT was used for determining the spatial position of the bony structures in an animal sample and co-registered with the MR images. The effect of the UTE sequence parameter flip angle (Flip), repetition time (T-R), echo time (T-E), image matrix size (Vox) and number of radial sampling spokes (Samp) were studied. The parameters were also investigated in a healthy voluntary and it was determined that the optimal UTE settings for high bone contrast in a clinically relevant set up were: Flip similar to 9 degrees and T-E = 0.07 ms, while T-R was kept at 8 ms, Vox at 192 and Samp at 30,000. The use of response surface maps, describing the modelled relation between bone contrast and UTE settings, founded in the DoE, may provide information and be a tool to more appropriately select suitable UTE sequence settings.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Magnetic resonance imaging
Ultra-short echo time
Experimental design
Bone contrast
Multiple linear regression

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy