Combining phase and magnitude information for contrast agent quantification in dynamic contrast-enhanced MRI using statistical modeling

Brynolfsson, Patrik (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Yu, Jun, 1962- (författare)
Umeå universitet,Institutionen för matematik och matematisk statistik,Mathematical Statistics
Wirestam, Ronnie (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Department of Medical Radiation Physics
visa fler...
Karlsson, Mikael (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Garpebring, Anders, 1980- (författare)
Umeå universitet,Institutionen för strålningsvetenskaper,CJ Gorter Center for High Field MRI, Leiden University Medical Center, Leiden, Netherlands
visa färre...
 (creator_code:org_t)
2014-10-16
2015
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley-Blackwell. - 0740-3194 .- 1522-2594. ; 74:4, s. 1156-1164
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: The purpose of this study was to investigate, using simulations, a method for improved contrast agent (CA) quantification in DCE-MRI.Methods: We developed a maximum likelihood estimator that combines the phase signal in the DCE-MRI image series with an additional CA estimate, e.g. the estimate obtained from magnitude data. A number of simulations were performed to investigate the ability of the estimator to reduce bias and noise in CA estimates. Noise levels ranging from that of a body coil to that of a dedicated head coil were investigated at both 1.5T and 3T.Results: Using the proposed method, the root mean squared error in the bolus peak was reduced from 2.24 to 0.11 mM in the vessels and 0.16 to 0.08 mM in the tumor rim for a noise level equivalent of a 12-channel head coil at 3T. No improvements were seen for tissues with small CA uptake, such as white matter.Conclusion: Phase information reduces errors in the estimated CA concentrations. A larger phase response from higher field strengths or higher CA concentrations yielded better results. Issues such as background phase drift need to be addressed before this method can be applied in vivo.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
NATURVETENSKAP  -- Matematik -- Sannolikhetsteori och statistik (hsv//swe)
NATURAL SCIENCES  -- Mathematics -- Probability Theory and Statistics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

dynamic contrast-enhanced MRI
contrast agent quantification
phase
inverse problem
inverse problem
phase
contrast agent quantification
dynamic contrast-enhanced MRI

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy