SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-95071"
 

Sökning: id:"swepub:oai:DiVA.org:umu-95071" > Sclerosing injectio...

Sclerosing injections and ultrasound-guided arthroscopicshaving for patellar tendinopathy : good clinical results and decreased tendon thickness after surgery-a medium-term follow-up study

Sunding, Kerstin (författare)
Karolinska Institutet
Willberg, Lotta (författare)
Umeå universitet,Idrottsmedicin
Werner, Suzanne (författare)
Karolinska Institutet
visa fler...
Alfredson, Håkan (författare)
Umeå universitet,Idrottsmedicin
Forssblad, Magnus (författare)
Karolinska Institutet
Fahlström, Martin (författare)
Umeå universitet,Professionell utveckling
visa färre...
 (creator_code:org_t)
2014-05-06
2015
Engelska.
Ingår i: Knee Surgery, Sports Traumatology, Arthroscopy. - : Springer Science and Business Media LLC. - 0942-2056 .- 1433-7347. ; 23:8, s. 2259-2268
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: Treatment of patellar tendinopathy/jumper's knee with ultrasound-guided sclerosing injections or ultrasound-guided arthroscopic shaving has shown good clinical short-term results. Former studies indicate that the tendon thickness and structure stays unaffected after successful treatment. The aim of this study was to evaluate the sonographic findings and clinical outcome 3-5 years after treatment of patellar tendinopathy with ultrasound-guided sclerosing injections or arthroscopic shaving.METHODS: Fifty-seven patellar tendons (43 patients) with chronic patellar tendinopathy were evaluated, with ultrasound, colour Doppler (CD) and visual analogue scale (VAS) for pain and satisfaction with treatment, 3-5 years after treatment. Functional status was evaluated with a single question-"Back in full loading activity?" yes or no.RESULTS: At endpoint (mean 46 months), there was a significant decrease in anteroposterior thickness of the proximal patellar tendon in patients treated with ultrasound-guided arthroscopic shaving but not after sclerosing injections. Tendon structure had improved, and CD local blood flow had diminished significantly in both groups. There were good clinical results with a significant decrease in VAS for pain after sclerosing injections (VAS 64 ± 18 → 17 ± 23) with 74 % satisfied patients and also after arthroscopic shaving (VAS 77 ± 16 → 13 ± 23) with 80 % satisfied patients. There were no significant differences in VAS between groups. A significant correlation between low local blood flow and high patient satisfaction was found.CONCLUSIONS: Tendon thickness decreased over time after ultrasound-guided arthroscopic shaving, and tendon structure and local blood flow decreased after both treatments. There were good, and similar, clinical results with both methods. LEVEL OF EVIDENCE: III.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy