Automated Assessment of Whole-Body Adipose Tissue Depots From Continuously Moving Bed MRI : A Feasibility Study
-
- Kullberg, Joel (författare)
- Uppsala universitet,Enheten för radiologi
-
- Johansson, Lars (författare)
- Uppsala universitet,Enheten för radiologi
-
- Ahlström, Håkan (författare)
- Uppsala universitet,Enheten för radiologi
-
visa fler...
-
- Courivaud, Frederic (författare)
- MR Clinical Science, Philips Healthcare, Oslo, Norway.
-
- Koken, Peter (författare)
- Philips Research Europe, Hamburg, Germany
-
- Eggers, Holger (författare)
- Philips Research Europe, Hamburg, Germany
-
- Börnert, Peter (författare)
- Philips Research Europe, Hamburg, Germany
-
visa färre...
-
(creator_code:org_t)
- Wiley, 2009
- 2009
- Engelska.
-
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 30:1, s. 185-193
- Relaterad länk:
-
https://onlinelibrar...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- PURPOSE: To present an automated algorithm for segmentation of visceral, subcutaneous, and total volumes of adipose tissue depots (VAT, SAT, TAT) from whole-body MRI data sets and to investigate the VAT segmentation accuracy and the reproducibility of all depot assessments. MATERIALS AND METHODS: Repeated measurements were performed on 24 volunteer subjects using a 1.5 Tesla clinical MRI scanner and a three-dimensional (3D) multi-gradient-echo sequence (resolution: 2.1 x 2.1 x 8 mm(3), acquisition time: 5 min 15 s). Fat and water images were reconstructed, and fully automated segmentation was performed. Manual segmentation of the VAT reference was performed by an experienced operator. RESULTS: Strong correlation (R = 0.999) was found between the automated and manual VAT assessments. The automated results underestimated VAT with 4.7 +/- 4.4%. The accuracy was 88 +/- 4.5% and 7.6 +/- 5.7% for true positive and false positive fractions, respectively. Coefficients of variation from the repeated measurements were: 2.32 % +/- 2.61%, 2.25% +/- 2.10%, and 1.01% +/- 0.74% for VAT, SAT, and TAT, respectively. CONCLUSION: Automated and manual VAT results correlated strongly. The assessments of all depots were highly reproducible. The acquisition and postprocessing techniques presented are likely useful in obesity related studies.
Nyckelord
- magnetic resonance imaging
- whole-body
- water-fat imaging
- visceral adipose tissue
- subcutaneous adipose tissue
- automated segmentation
- MEDICINE
- MEDICIN