SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:uu-104030"
 

Search: id:"swepub:oai:DiVA.org:uu-104030" > Visual and optical ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Visual and optical performance of the Akreos Adapt Advanced Optics and Tecnis Z9000 intraocular lenses. Swedish multicenter study

Johansson, Björn (author)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Oftalmiatrik,Ögonkliniken US/LiM
Sundelin, Staffan (author)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation,Institute of Clinical Neuroscience, Göteborg University, Göteborg
Wikberg-Matsson, Anna (author)
Uppsala universitet,Institutionen för neurovetenskap,oftalmiatrik,Section of Ophthalmology, Göteborg University, Göteborg
show more...
Unsbo, Peter (author)
KTH,Biomedicinsk fysik och röntgenfysik,Department of Applied Physics, Stockholm
Behndig, Anders (author)
Umeå universitet,Oftalmiatrik,Department of Clinical Science/Ophthalmology, Umeå University Hospital, Umeå, Sweden
show less...
 (creator_code:org_t)
Ovid Technologies (Wolters Kluwer Health), 2007
2007
English.
In: Journal of cataract and refractive surgery. - : Ovid Technologies (Wolters Kluwer Health). - 0886-3350 .- 1873-4502. ; 33:9, s. 1565-1572
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PURPOSE: To compare the subjective visual and objective optical performance of 2 aspherical intraocular lenses (lOLs), the Akreos Adapt Advanced Optics (AO) (Bausch & Lomb, Inc.) and the Tecnis Z9000 (Advanced Medical Optics, Inc.). SETTING: Four university hospitals in Sweden. METHODS: This study comprised 80 patients, 20 each from 4 university hospital centers in Sweden. All patients had bilateral clear corneal phacoemulsification with implantation of an Akreos Adapt AO IOL in 1 eye and Tecnis Z9000 IOL in the other eye according to a randomization protocol. Preoperatively, 90% contrast Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity was measured and the mesopic pupil sizes were determined. Ten to 12 weeks postoperatively, 12.5% and 90% contrast ETDRS visual acuities and photopic and mesopic Functional Acuity Contrast Test chart contrast sensitivities were determined. Wavefront analysis was performed with the Zywave II aberrometer (Bausch & Lomb, Inc.), and a questionnaire on the subjective quality of vision was completed by each patient. RESULTS: The Akreos AO IOL and Tecnis Z9000 IOL produced similar high- and low-contrast visual acuities as well as photopic and mesopic contrast sensitivities. The Tecnis Z9000 IOL resulted in lower spherical aberrations of the eye (mean 0.05 ± 0.13 μm versus 0.35 ± 0.13 μm root mean square, 6.0 mm pupil) (P<.001); however, the Akreos AO IOL provided a larger depth of field (mean 1.22 diopter [D] ± 0.48 [SD] versus 0.86 ± 0.50 D, 6.0 mm pupil) (P<.001). Patient satisfaction was generally high, although 68.8% of the patients reported some type of visual disturbance postoperatively. Twenty-eight percent of patients reported better subjective visual quality in the Akreos AO eye and 14%, in the Tecnis Z9000 eye (P<.0001). Accordingly, 33% perceived more visual disturbances in the Tecnis Z9000 eye and 11%, in the Akreos AO eye (P<.0001). CONCLUSIONS: Maximum reduction of spherical aberration did not maximize subjective visual quality. The higher perceived quality of vision with the Akreos AO IOL could be because of differences in depth of field, lOL material, or IOL design.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

Treatment
Human
Ophthalmology
Surgery
Multicenter study
Swedish
Intraocular lens
Optics
Advanced stage
Visual performance
MEDICINE
MEDICIN
contrast sensitivity
capsule opacification
pseudophakic patients
spherical-aberration
decentration
silicone
quality
acuity
eyes
implantation

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view