SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-105140"
 

Sökning: id:"swepub:oai:DiVA.org:uu-105140" > Three-dimensional t...

Three-dimensional time-of-flight (3D TOF) magnetic resonance angiography (MRA) and contrast-enhanced MRA of intracranial aneurysms treated with platinum coils

Wikström, Johan, 1964- (författare)
Uppsala universitet,Enheten för radiologi
Ronne-Engström, E. (författare)
Uppsala universitet,Neurokirurgi
Gal, Gyula (författare)
Uppsala universitet,Enheten för radiologi
visa fler...
Enblad, P. (författare)
Uppsala universitet,Neurokirurgi
Tovi, Metin (författare)
Uppsala universitet,Enheten för radiologi
visa färre...
 (creator_code:org_t)
2008-03-01
2008
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 49:2, s. 190-6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Contrast-enhanced magnetic resonance angiography (CE-MRA) is less prone to flow-related signal intensity loss than three-dimensional time-of-flight (3D TOF) MRA and may therefore be more sensitive for detection of residual patency in platinum coil-treated intracranial aneurysms. Purpose: To compare MRA and CE-MRA in the follow-up of intracranial aneurysms treated with platinum coils. MATERIAL AND METHODS: CE-MRA and 3D TOF MRA (pre- and postcontrast injection) of the intracranial vasculature was performed at 1.5T in 38 patients (47 aneurysms) referred for DSA in the follow-up of coiled intracranial aneurysms. RESULTS: DSA showed aneurysm patency in 22/47 investigations. Patent aneurysm components were observed with CE-MRA in 18/22 cases, and with 3D TOF MRA in 21/22 cases. There was no significant difference in patent aneurysm component size between CE-MRA and 3D TOF MRA. In addition, CE-MRA showed six, 3D TOF MRA before contrast injection showed seven, and 3D TOF MRA after contrast injection showed eight cases with patent aneurysm components not observed on DSA. CONCLUSION: 3D TOF MRA was highly sensitive for detection of patent aneurysm components, and at least as sensitive as CE-MRA. Residual aneurysm patency seems to be better visualized with MRA than with DSA in some cases.

Nyckelord

Adults
aneurysms
CNS
contrast agents
intravenous
MR angiography
vascular
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy