Broadband power-line communications : The channel capacity analysis

Anatory, Justinian (författare)
Uppsala universitet,Elektricitetslära,University of Dar es Salaam, Tanzania
Theethayi, Nelson (författare)
Uppsala universitet,Elektricitetslära,Uppsala University
Thottappillil, Rajeev (författare)
Uppsala universitet,Elektricitetslära,Uppsala University
visa fler...
Kissaka, Mussa M. (författare)
University of Dar es Salaam, Dar es Salaam, Tanzania
Mvungi, Nerey H. (författare)
University of Dar es Salaam, Dar es Salaam, Tanzania
visa färre...
 (creator_code:org_t)
2008
2008
Engelska.
Ingår i: IEEE Transactions on Power Delivery. - 0885-8977 .- 1937-4208. ; 23:1, s. 164-170
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The power line has been proposed as a solution to deliver broadband services to end users. Various studies in the recent past have reported a decrease in channel capacity with an increase-in the number of branches for a given channel type whether it is an indoor or low-voltage (LV) or medium-voltage (MV) channel. Those studies, however, did not provide a clear insight as to how the channel capacity is related to the number of distributed branches along the line. This paper attempts to quantify and characterize the effects of channel capacity in relation to the number of branches and with different terminal loads for a given type of channel. It is shown that for a power spectral density (PSD) between -90 dBm/Hz to - 30 dBm/Hz, the channel capacity decreases by a 20-30 Mb/s/branch, 14-24 Mb/s/branch, and a 20-25 Mb/s/branch for an MV channel, LV channel, and indoor channel, respectively. It is also shown that the channel capacity is minimum when the load impedance is terminated in characteristic impedances for any type of channel treated here. It is shown that there could be a significant loss in channel capacity if a ground return was used instead of a conventional adjacent conductor return. The analysis presented in this paper would help in designing appropriate power-line communication equipment for better and efficient data transfer.

Nyckelord

branched network
broadband power line
channel capacity
frequency response
indoor channel
low-voltage (LV) channel
medium-voltage (MV) channel
multipath
power-line channel
transfer function
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy