SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-150290"
 

Sökning: id:"swepub:oai:DiVA.org:uu-150290" > Capillary electroph...

Capillary electrophoresis with laser-induced fluorescence detection : a sensitive method for monitoring extracellular concentrations of amino acids in the periaqueductal grey matter.

Bergquist, Jonas (författare)
Institute of Clinical Neuroscience, Department of Psychiatry and Neurochemistry, Göteborg University, Mölndal Hospital
Vona, M J (författare)
Institute of Clinical Neuroscience, Department of Psychiatry and Neurochemistry, Göteborg University, Mölndal Hospital
Stiller, C O (författare)
Karolinska Institutet
visa fler...
O'Connor, W T (författare)
Department of Physiology and Pharmacology, Division of Pharmacology, Karolinska Institute
Falkenberg, T (författare)
Karolinska Institutet
Ekman, R (författare)
Institute of Clinical Neuroscience, Department of Psychiatry and Neurochemistry, Göteborg University, Mölndal Hospital
visa färre...
 (creator_code:org_t)
Elsevier BV, 1996
1996
Engelska.
Ingår i: Journal of Neuroscience Methods. - : Elsevier BV. - 0165-0270 .- 1872-678X. ; 65:1, s. 33-42
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The use of capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) for the analysis of microdialysate samples from the periaqueductal grey matter (PAG) of freely moving rats is described. By employing 3-(4-carboxybenzoyl)-2-quinoline-carboxaldehyde (CBQCA) as a derivatization agent, we simultaneously monitored the concentrations of 8 amino acids (arginine, glutamine, valine, gamma-amino-n-butyric acid (GABA), alanine, glycine, glutamate, and aspartate), with nanomolar and subnanomolar detection limits. Two of the amino acids (GABA and glutamate) were analysed in parallel by conventional high-performance liquid chromatography (HPLC) in order to directly compare the two analytical methods. Other CE methods for analysis of microdialysate have been previously described, and this improved method offers greater sensitivity, ease of use, and the possibility to monitor several amino acids simultaneously. By using this technique together with an optimised form of microdialysis technique, the tiny sample consumption and the improved detection limits permit the detection of fast and transient transmitter changes.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy