SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-150729"
 

Sökning: id:"swepub:oai:DiVA.org:uu-150729" > Radiation tolerance...

Radiation tolerance of a spin-dependent tunnelling magnetometer for space applications

Persson, Anders (författare)
Uppsala universitet,Mikrosystemteknik,ÅSTC
Thornell, Greger (författare)
Uppsala universitet,Mikrosystemteknik,ÅSTC
Nguyen, Hugo (författare)
Uppsala universitet,Mikrosystemteknik,ÅSTC
 (creator_code:org_t)
2011-02-23
2011
Engelska.
Ingår i: Measurement science and technology. - : IOP Publishing. - 0957-0233 .- 1361-6501. ; 22:4, s. 045204-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To meet the increasing demand for miniaturized space instruments, efforts have been made to miniaturize traditional magnetometers, e. g. fluxgate and spin-exchange relaxation-free magnetometers. These have, for different reasons, turned out to be difficult. New technologies are needed, and promising in this respect are tunnelling magnetoresistive (TMR) magnetometers, which are based on thin film technology. However, all new space devices first have to be qualified, particularly in terms of radiation resistance. A study on TMR magnetometers' vulnerability to radiation is crucial, considering the fact that they employ a dielectric barrier, which can be susceptible to charge trapping from ionizing radiation. Here, a TMR-based magnetometer, called the spin-dependent tunnelling magnetometer (SDTM), is presented. A magnetometer chip consisting of three Wheatstone bridges, with an angular pitch of 120 degrees, was fabricated using microstructure technology. Each branch of the Wheatstone bridges consists of eight pairs of magnetic tunnel junctions (MTJs) connected in series. Two such chips are used to measure the three-dimensional magnetic field vector. To investigate the SDTM's resistance to radiation, one branch of a Wheatstone bridge was irradiated with gamma rays from a Co-60 source with a dose rate of 10.9 rad min(-1) to a total dose of 100 krad. The TMR of the branch was monitored in situ, and the easy axis TMR loop and low-frequency noise characteristics of a single MTJ were acquired before and after irradiation with the total dose. It was concluded that radiation did not influence the MTJs in any noticeable way in terms of the TMR ratio, coercivity, magnetostatic coupling or low-frequency noise.

Nyckelord

radiation tolerant
magnetic tunnel junction
tunnelling magnetoresistance
magnetometer
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Persson, Anders
Thornell, Greger
Nguyen, Hugo
Artiklar i publikationen
Measurement scie ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy