SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-151901"
 

Sökning: id:"swepub:oai:DiVA.org:uu-151901" > Multicenter analyti...

Multicenter analytical evaluation of a high-sensitivity troponin T assay

Saenger, A. K. (författare)
Beyrau, R. (författare)
Braun, S. (författare)
visa fler...
Cooray, Ruby (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper
Dolci, A. (författare)
Freidank, H. (författare)
Giannitsis, E. (författare)
Gustafson, S. (författare)
Handy, B. (författare)
Katus, H. (författare)
Melanson, S. E. (författare)
Panteghini, M. (författare)
Venge, Per (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper
Zorn, M. (författare)
Jarolim, P. (författare)
Bruton, D. (författare)
Jarausch, J. (författare)
Jaffe, A. S. (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2011
2011
Engelska.
Ingår i: Clinica Chimica Acta. - : Elsevier BV. - 0009-8981 .- 1873-3492. ; 412:9-10, s. 748-754
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: High-sensitivity cardiac troponin assays are being introduced clinically for earlier diagnosis of acute myocardial infarction (AMI). We evaluated the analytical performance of a high-sensitivity cardiac troponin T assay (hscTnT. Roche Diagnostics) in a multicenter, international trial. Methods: Three US and 5 European sites evaluated hscTnT on the Modular (R) Analytics E170, cobas (R) 6000, Elecsys 2010, and cobas (R) e 411. Precision, accuracy, reportable range, an inter-laboratory comparison trial, and the 99th percentile of a reference population were assessed. Results: Total imprecision (CVs) were 4.6-36.8% between 3.4 and 10.3 ng/L hscTnT. Assay linearity was up to 10,000 ng/L and the limit of blank and detection were 3 and 5 ng/L, respectively. The 99th percentile reference limit was 14.2 ng/L (n = 533). No significant differences between specimen types, assay incubation time, or reagent lots existed. A substantial positive bias (76%) exists between the 4th generation and hscTnT assays at the low end of the measuring range (< 50 ng/L). hscTnT serum pool concentrations were within 2SD limits of the mean of means in the comparison trial, indicating comparable results across multiple platforms and laboratories. Conclusion: The Roche hscTnT assay conforms to guideline precision requirements and will likely identify additional patients with myocardial injury suspicious for AMI.

Nyckelord

Troponin
99th percentile
High-sensitivity
Acute myocardial infarction
Cardiac biomarkers
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy