SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-16680"
 

Sökning: id:"swepub:oai:DiVA.org:uu-16680" > Surface-adsorbed fi...

Surface-adsorbed fibrinogen and fibrin may activate the contact activation system

Sanchez, Javier (författare)
Uppsala universitet,Enheten för klinisk immunologi
Elgue, Graciela (författare)
Uppsala universitet,Enheten för klinisk immunologi
Larsson, Rolf (författare)
Uppsala universitet,Enheten för klinisk immunologi
visa fler...
Nilsson, Bo (författare)
Uppsala universitet,Enheten för klinisk immunologi
Olsson, P (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2008
2008
Engelska.
Ingår i: Thrombosis Research. - : Elsevier BV. - 0049-3848 .- 1879-2472. ; 122:2, s. 257-263
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • INTRODUCTION: This study was designed to investigate whether fibrinogen, soluble desAA-fibrin, and insoluble desAABB-fibrin are able to induce clotting by triggering the plasma contact activation system when adsorbed to polystyrene. MATERIALS AND METHODS: The above-mentioned substances were individually prepared on polystyrene meshwork squares, and then exposed to a purified FXII solution or non-calcium containing plasma (citrated and dialyzed normal pooled plasma) in polystyrene cuvettes coated with surface-immobilized heparin, to completely block contact activation and the coagulation mechanism that might be induced by the cuvette surfaces. Sodium glass beads were used as the reference material. RESULTS: On exposure to purified FXII solution and plasma, all the tested materials adsorbed and activated FXII to varying degrees. This activation led to the formation of FXIa in the exposed plasma, with the highest activation occurring upon exposure to glass, desAA-fibrin and desAABB-fibrin and the lowest upon exposure to fibrinogen-adsorbed or unmodified polystyrene meshwork squares. Following recalcification, in cuvettes with surface-immobilized heparin, a spectrophotometric assay showed that the surface-exposed plasma aliquots clotted within 5 min after contact with glass, within 10 to 15 min after contact with the two forms of fibrin, and somewhat longer after contact with adsorbed fibrinogen. The longest lag phase, close to 20 min, occurred in plasma exposed to unmodified polystyrene meshwork. Whole blood deposited in surface heparinized cuvettes directly from the cubital vein did not clot during the observation time (2 h). CONCLUSIONS: These results indicate that domains induced by conformational changes in adsorbed fibrinogen and fibrin are capable of activating adsorbed proenzymes and that various forms of fibrin are considerably stronger activators of the contact activation system than are adsorbed fibrinogen or a polystyrene meshwork. The delayed coagulation in plasma exposed to the unmodified polystyrene meshwork can be explained by a two-step process: first, adsorption of fibrinogen, and second, activation of FXII. Under our experimental conditions, the adsorption and activation of FXII on fibrinogen and fibrin seems to be an important mechanism for triggering coagulation.

Nyckelord

Coagulation
Contact activation
Fibrin
Fibrinogen
Surface-immobilized heparin
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy