SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-17082"
 

Sökning: id:"swepub:oai:DiVA.org:uu-17082" > The exactness of le...

The exactness of left ventricular segmentation in cine magnetic resonance imaging and its impact on systolic function values

Ebeling Barbier, Charlotte (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,Ahlström
Johansson, Lars (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,Ahlström
Lind, Lars (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper
visa fler...
Ahlström, Håkan (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,Ahlström
Bjerner, Thomas (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,Ahlström
visa färre...
 (creator_code:org_t)
2016-08-30
2007
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 48:3, s. 285-291
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To evaluate the impact of exactness of the segmentation of the left ventricle (LV), using cine magnetic resonance imaging (MRI). Material and methods: Steady-state free-precession cine MRI was performed on 100 randomly selected subjects. Myocardial borders were outlined on short-axis images using three methods: method 1 was computer assisted, excluding papillary muscles from the left ventricular mass (LVM); method 2 was similar but included papillary muscles; and method 3 was manually traced including papillary muscles. LV end-systolic (ES) and end-diastolic (ED) masses and volumes, ejection fraction (EF), stroke volume (SV), and cardiac output (CO) were calculated from these measurements. The difference between the ES and ED LVM was used to estimate the exactness of the methods. Results: Method 3 was the most exact, and method 1 was the least exact. The three methods generated differing EF, SV, and CO measurements. With an ES-ED LVM difference exceeding 20 g, the mean SV measurement error was 8.83.6 ml. Conclusion: Manual tracing proved more exact than computer-assisted quantification. Exactness had an impact on EF, SV, and CO measurements, and the ES-ED LVM difference can be used to identify assessments that would benefit from more exact segmentation.

Nyckelord

Adults
Cardiac
Heart
Left ventricle
MR imaging
Segmentation
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy