SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:uu-189086"
 

Search: id:"swepub:oai:DiVA.org:uu-189086" > Quantitative Parame...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Quantitative Parametric Perfusion Images Using 15O-Labeled Water and a Clinical PET/CT Scanner : test-retest variability in lung cancer

van der Veldt, Astrid A M (author)
Hendrikse, N Harry (author)
Harms, Hendrik J (author)
show more...
Comans, Emile F I (author)
Postmus, Pieter E (author)
Smit, Egbert F (author)
Lammertsma, Adriaan A (author)
Lubberink, Mark (author)
Department of Nuclear Medicine and PET Research, VU University Medical Center, Amsterdam, The Netherlands
show less...
 (creator_code:org_t)
2010-10-18
2010
English.
In: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 51:11, s. 1684-1690
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Quantification of tumor perfusion using radioactive water (H215O) and PET is a promising method for monitoring treatment with antiangiogenic agents. However, use of dynamic H215O scans together with a fully 3-dimensional clinical PET/CT scanner needs to be validated. The purpose of the present study was to assess validity and reproducibility of dynamic H215O PET/CT scans for measuring tumor perfusion and validate the quantitative accuracy of parametric perfusion images.Methods:Eleven patients with non–small cell lung cancer were included in this study. Patients underwent 2 dynamic H215O (370 MBq) PET scans on the same day. During the first scan, arterial blood was withdrawn continuously. Input functions were derived from blood sampler data and the ascending aorta as seen in the images themselves (image-derived input function [IDIF]). Parametric perfusion images were computed using a basis function implementation of the standard single-tissue-compartment model. Volumes of interest (VOIs) were delineated on low-dose CT (LD-CT) and parametric perfusion images.Results:VOIs could be accurately delineated on both LD-CT and parametric perfusion images. These parametric perfusion images had excellent image quality and quantitative accuracy when compared with perfusion values determined by nonlinear regression. Good correlation between perfusion values derived from the blood sampler input function and IDIF was found (Pearson correlation coefficient, r = 0.964; P < 0.001). Test–retest variability of tumor perfusion was 16% and 20% when delineated on LD-CT and parametric perfusion images, respectively.Conclusion:The use of ascending aorta IDIFs is an accurate alternative to arterial blood sampling for quantification of tumor perfusion. Image quality obtained with a clinical PET/CT scanner enables generation of accurate parametric perfusion images. VOIs delineated on LD-CT have the highest reproducibility, and changes of more than 16% in tumor perfusion are likely to represent treatment effects.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view