Sökning: id:"swepub:oai:DiVA.org:uu-213823" >
Reabsorption atelec...
Reabsorption atelectasis in a porcine model of ARDS : regional and temporal effects of airway closure, oxygen, and distending pressure
-
- Derosa, Savino (författare)
- Uppsala universitet,Hedenstiernalaboratoriet,Anestesiologi och intensivvård
-
- Borges, João Batista (författare)
- Uppsala universitet,Hedenstiernalaboratoriet,Klinisk fysiologi
-
- Segelsjö, Monica (författare)
- Uppsala universitet,Enheten för radiologi
-
visa fler...
-
Tannoia, Angela (författare)
-
Pellegrini, Mariangela (författare)
-
- Larsson, Anders (författare)
- Uppsala universitet,Hedenstiernalaboratoriet,Anestesiologi och intensivvård
-
Perchiazzi, Gaetano (författare)
-
- Hedenstierna, Göran (författare)
- Uppsala universitet,Klinisk fysiologi,Hedenstiernalaboratoriet
-
visa färre...
-
(creator_code:org_t)
- American Physiological Society, 2013
- 2013
- Engelska.
-
Ingår i: Journal of applied physiology. - : American Physiological Society. - 8750-7587 .- 1522-1601. ; 115:10, s. 1464-1473
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Little is known about the small airways dysfunction in acute respiratory distress syndrome (ARDS). By computed tomography (CT) imaging in a porcine experimental model of early ARDS, we aimed at studying the location and magnitude of peripheral airway closure and alveolar collapse under high and low distending pressures and high and low inspiratory oxygen fraction (FIO2). Six piglets were mechanically ventilated under anesthesia and muscle relaxation. Four animals underwent saline-washout lung injury, and two served as healthy controls. Beyond the site of assumed airway closure, gas was expected to be trapped in the injured lungs, promoting alveolar collapse. This was tested by ventilation with an FIO2 of 0.25 and 1 in sequence during low and high distending pressures. In the most dependent regions, the gas/tissue ratio of end-expiratory CT, after previous ventilation with FIO2 0.25 low-driving pressure, was significantly higher than after ventilation with FIO2 1; with high-driving pressure, this difference disappeared. Also, significant reduction in poorly aerated tissue and a correlated increase in nonaerated tissue in end-expiratory CT with FIO2 1 low-driving pressure were seen. When high-driving pressure was applied or after previous ventilation with FIO2 0.25 and low-driving pressure, this pattern disappeared. The findings suggest that low distending pressures produce widespread dependent airway closure and with high FIO2, subsequent absorption atelectasis. Low FIO2 prevented alveolar collapse during the study period because of slow absorption of gas behind closed airways.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Physiology (hsv//eng)
Nyckelord
- small airways dysfunction
- absorption atelectasis
- acute respiratory distress syndrome
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas