SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-224922"
 

Sökning: id:"swepub:oai:DiVA.org:uu-224922" > The role of a simul...

The role of a simulator-based course in coronary angiography on performance in real life cath lab

Jensen, Ulf J. (författare)
Karolinska Institutet
Jensen, Jens (författare)
Olivecrona, Göran (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Ahlberg, Gunnar (författare)
Karolinska Institutet
Lagerquist, Bo (författare)
Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),Institutionen för medicinska vetenskaper
Tornvall, Per (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2014-03-12
2014
Engelska.
Ingår i: BMC Medical Education. - : Springer Science and Business Media LLC. - 1472-6920. ; 14, s. 49-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: The aim of this study was to explore if a course consisting of lectures combined with simulator training in coronary angiography (CA) could accelerate the early learning curve when performing CA on patients. Knowledge in performing CA is included in the curriculum for the general cardiologist. The method, according to American College of Cardiology and European Society of Cardiology guidelines, for this training is not well defined but simulator training is proposed to be an option. However, the transfer effect from a CA simulator to performance in real world cath lab is not validated. Methods: Fifty-four residents without practical skills in CA completed the course and 12 continued to training in invasive cardiology. These residents were tracked in the Swedish Coronary Angiography and Angioplasty Registry and compared to a control group of 46 novel operators for evaluation of performance metrics. A total of 4472 CAs were analyzed. Results: Course participants demonstrated no consistent acceleration in the early learning curve in real world cath lab. They had longer fluoroscopy time compared to controls (median 360 seconds (IQR 245-557) vs. 289 seconds (IQR 179-468), p < 0.001). Safety measures also indicated more complications appearing at the ward, in particular when using the femoral approach (6.25% vs. 2.53%, p < 0.001). Conclusions: Since the results of this retrospective non-randomized study were negative, the role of a structured course including simulator training for skills acquisition in CA is still uncertain. Randomized transfer studies are warranted to justify further use of simulators for training in CA

Ämnesord

SAMHÄLLSVETENSKAP  -- Utbildningsvetenskap (hsv//swe)
SOCIAL SCIENCES  -- Educational Sciences (hsv//eng)

Nyckelord

Learning curve
Simulator
Performance
Coronary angiography
Learning curve
Simulator
Performance
Coronary angiography

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy