Novel sensitive cardiac troponin I immunoassay free from troponin I-specific autoantibody interference

Savukoski, Tanja (författare)
Jacobino, Jenna (författare)
Laitinen, Paivi (författare)
visa fler...
Lindahl, Bertil (författare)
Uppsala universitet,Kardiologi,Uppsala kliniska forskningscentrum (UCR)
Venge, Per (författare)
Uppsala universitet,Biokemisk struktur och funktion
Ristiniemi, Noora (författare)
Wittfooth, Saara (författare)
Pettersson, Kim (författare)
visa färre...
 (creator_code:org_t)
Walter de Gruyter GmbH, 2014
2014
Engelska.
Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 52:7, s. 1041-1048
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Cardiac troponins (cTnI and cTnT) are the recommended biomarkers of myocardial infarction. As cTn-specific autoantibodies (cTnAAb) can interfere with the cTn detection by state-of-the-art cTnI assays, our objective was to develop a sensitive cTnI immunoassay free from this analytical interference. Methods: The assay used antibody-coated spots containing three capture Mabs/Fabs directed against the N-terminus, midfragment and C-terminus of cTnI and a europium chelate-labeled tracer Mab against the C-terminus. Following a 3-h sample incubation and washing, cTnI was quantified by time-resolved fluorometry. Results: The limit of detection (LoD) was 2.9 ng/L and the assay was linear up to 50,000 ng/L. The total precision of 10% CV was not reached, but 20% CV was reached at 10 ng/L. Mean cTnI (10-50,000 ng/L) recoveries were 100% and 119% in three cTnAAb-positive and two cTnAAb-negative individuals, respectively, verifying the interference resistance of the antibody design used. On average, Architect hs-cTnI assay gave seven-fold higher cTnI concentrations than the new assay but the correlation between the assays was good (r=0.958). Of apparently healthy individuals (n=159), 18% had measurable cTnI values (>LoD) and 10% were cTnAAb-positive. The proportion of measurable cTnI values, however, was significantly higher in cTnAAb-positive individuals (13/16, median cTnI 8.5 ng/L) than in cTnAAb-negative individuals (15/143, median cTnI

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Nyckelord

antibody-coated spot
autoantibody
cardiac troponin I
immunoassay
interference
myocardial infarction

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy