Sökning: onr:"swepub:oai:DiVA.org:uu-236324" >
Management of malfu...
Management of malfunctioning and recalled pacemaker and defibrillator leads : results of the European Heart Rhythm Association survey
-
Grazia Bongiorni, Maria (författare)
-
Dagres, Nikolaos (författare)
-
Estner, Heidi (författare)
-
visa fler...
-
Pison, Laurent (författare)
-
Todd, Derick (författare)
-
- Blomström-Lundqvist, Carina (författare)
- Uppsala universitet,Kardiologi-arrytmi
-
visa färre...
-
(creator_code:org_t)
- 2014-10-25
- 2014
- Engelska.
-
Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 16:11, s. 1674-1678
- Relaterad länk:
-
https://academic.oup...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The aim of this survey was to describe the different strategies regarding the management of malfunctioning and recalled pacemaker and defibrillator leads across Europe. A questionnaire has been designed to assess the current practice and physician's approach to the management of leads which are faulty, unnecessary, and/or recalled. Responses to the questionnaire were received from 34 hospitals-members of the European Heart Rhythm Association (EHRA) electrophysiology (EP) research network. The survey involved both very high and low volume implanting centres, with 85% of the responding centres performing lead extraction. The survey provides a panoramic view of operator's decision making in the field of malfunctioning, recalled, and redundant leads and outlines a common point of view on lead abandonment and factors influencing the decision about lead extraction. The main factors strongly influencing the decision making were patient's age (59%), the presence of the damaged leads (44%), and the lead dwelling time (44%). Regarding the lead abandonment, the main concern (61%) was the potential greater difficulty associated with lead extraction in the future. High volume extracting centres showed a greater propensity to removing the malfunctioning or recalled leads compared with low volume or non-extracting centres. This EP Wire survey gives a snapshot of the operators' approaches and options regarding redundant, malfunctioning, and recalled lead management and may form the basis for future prospective research on this topic.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- Kardiologi
- Cardiology
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
-
Europace
(Sök värdpublikationen i LIBRIS)
Till lärosätets databas