SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-241736"
 

Sökning: id:"swepub:oai:DiVA.org:uu-241736" > Biomimetic Hydroxya...

Biomimetic Hydroxyapatite Coated Titanium Screws Demonstrate Rapid Implant Stabilization and Safe Removal In-Vivo

Sörensen, Jan Henrik (författare)
Dürselen, Lutz (författare)
Welch, Ken, 1968- (författare)
Uppsala universitet,Nanoteknologi och funktionella material
visa fler...
Sörensen, Torben Christian (författare)
Procter, Philip (författare)
Engqvist, Håkan (författare)
Uppsala universitet,Tillämpad materialvetenskap
Strömme, Maria, 1970- (författare)
Uppsala universitet,Nanoteknologi och funktionella material
Ignatius, Anita (författare)
Steckel, Hartwig (författare)
visa färre...
 (creator_code:org_t)
Scientific Research Publishing, Inc. 2015
2015
Engelska.
Ingår i: Journal of Biomaterials and Nanobiotechnology. - : Scientific Research Publishing, Inc.. - 2158-7027 .- 2158-7043. ; 6, s. 20-35
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The early fixation of bone screws after surgical implantation still remains a challenge in the fieldof traumatology. Whilst hydroxyapatite (HA) coatings are known to enhance the fixation of implants;their removal at a later time-point may be problematic. An HA coating has been developedto demonstrate that both implant fixation and safe removal are feasible in the same design. Accordinglythe aim of this study was to compare the in-vivo performance of thin biomimetic HA coatedtitanium screws to uncoated counterparts used as control after bilateral implantation in the femoralcondyle of 36 New Zealand White Rabbits. The screws were analysed macroscopically, byhistology, micro-CT and biomechanically at both two and six weeks post-implantation. The HAcoated screws demonstrated excellent biocompatibility. At two weeks the HA coated screws demonstrateda significant increase in removal torque values as well as a strong trend towards higherpull-out forces. In addition histology confirmed a higher degree of osseointegration and directbone to implant contact. At six weeks no difference in pull-out force and removal torque could bedetected. SEM images confirmed the absence of any residual HA coating indicating a fast coatingdegradation in-vivo. The low level of removal torque after full osseointegration at 6 weeks supportsthe feasibility of safe and easy removal of the implant. The HA coating under study appearsto offer a unique characteristic of enhanced fixation with a minimal increase in removal torqueafter full osseointegration. This may be of value in clinical applications where it is necessary toassure both screw fixation and later removal.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Nanoteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Nano-technology (hsv//eng)

Nyckelord

Teknisk fysik med inriktning mot nanoteknologi och funktionella material
Engineering Science with specialization in Nanotechnology and Functional Materials
Teknisk fysik med inriktning mot materialvetenskap
Engineering Science with specialization in Materials Science

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy