Sökning: id:"swepub:oai:DiVA.org:uu-252182" >
Simultaneous or Del...
Simultaneous or Delayed Placement of Surface Modified and Fluoridated Dental Implants into Autogenous Block Bone Grafts : A Histologic and Biomechanical Study in the Rabbit
-
- Dasmah, Amir (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
-
- Rasmusson, Carl (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
-
- Thor, Andreas (författare)
- Uppsala universitet,Käkkirurgi
-
visa fler...
-
- Rasmusson, Lars, 1962 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
-
visa färre...
-
(creator_code:org_t)
- 2013-06-07
- 2015
- Engelska.
-
Ingår i: Clinical Implant Dentistry and Related Research. - : Wiley. - 1523-0899 .- 1708-8208. ; 17:2, s. 395-401
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://gup.ub.gu.se...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: A delayed approach is recommended for reconstruction of the jaws with autogenous bone grafts and dental implants. Experimental studies have shown stronger bone tissue responses to surface modified implants than to nonmodified ones. AimThe aim of the study was to evaluate bone integration and stability of surface modified and fluoridated implants when placed with fresh or healed autogenous bone grafts. Material and Methods: Six rabbits were used in this study. Each right rabbit tibia (control) received an autogenous bone graft, harvested from the calvarium. Eight weeks later, a second graft was harvested from the other side of the calvarium and placed on the left tibia (test) with an implant. Another implant was installed in the healed graft of the right tibia. TiO2-blasted and fluoridated OsseoSpeed(TM) implants (Astra Tech AB, Molndal, Sweden), 3.5mm in diameter and 9mm long, were used. After additional 8 weeks, the rabbits were sacrificed and the implants were removed en bloc for light-microscopic analysis. Bone-to-implant contact (BIC) was registered as well as the amount of bone filling a rectangle indicating a region of interest (ROI). Resonance frequency analysis (RFA) was conducted both at the time of surgery and at the end of the experiment. ResultsThere were no statistically significant differences either in BIC or ROI between the test and control sides. RFA showed higher implant stability for the control side at the time of the surgery, but the difference had leveled out at the time of the sacrifice. Conclusion: The present study showed similar bone tissue responses and stability for surface modified and fluoridated implants after 8 weeks of healing in fresh or healed autogenous bone grafts.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Nyckelord
- autogenous bone graft
- histological analysis
- implant
- implant surface
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas