SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-257639"
 

Sökning: id:"swepub:oai:DiVA.org:uu-257639" > Higher Frequency of...

Higher Frequency of Anastomotic Leakage with Stapled Compared to Hand-Sewn Ileocolic Anastomosis in a Large Population-Based Study

Gustafsson, Pontus (författare)
Karolinska Institutet
Jestin, Pia (författare)
Uppsala universitet,Kolorektalkirurgi
Gunnarsson, Ulf (författare)
Umeå universitet,Kirurgi
visa fler...
Lindforss, Ulrik (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2015-02-24
2015
Engelska.
Ingår i: World Journal of Surgery. - : Springer Science and Business Media LLC. - 0364-2313 .- 1432-2323. ; 39:7, s. 1834-1839
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The stapling technique was recommended in a recent Cochrane analysis based on relatively small randomized trials between 1970 and 2009. Data from a large Swedish population-based quality register were analyzed in order to compare the leakage frequency between stapled and hand-sewn ileocolic anastomoses in colon cancer surgery. Three-thousand four-hundred and twenty-eight patients with an ileocolic anastomosis were entered in a Swedish regional quality register for colon cancer, including the type of anastomosis used. The patients were analyzed by logistic regression regarding risk for leakage, and Cox proportional hazard regression for survival associated with the technique used for anastomosis. Analyses were made for gender, age, elective or emergency surgery, duration of surgery, bleeding, cancer stage, and local radicality. Most anastomoses were hand sewn (1,908 of 3,428, 55.7 %, p < 0.001), whereas stapling was more common among emergency cases (342 of 618, 55.3 %, p < 0.001). Clinically relevant leakage appeared in 58 patients (1.7 %), of whom 51 (87.9 %) were re-operated. Leakage was found to be more frequent after stapled anastomosis (2.4 vs. 1.2 %, p = 0.006), and in multivariate analysis, stapled anastomosis was the only risk factor (OR = 2.04 95 % CI 1.19-3.50). There was no difference in overall survival related to the technique. Hand-sewn anastomosis is not associated with a higher leakage rate when comparing to a stapling procedure and is recommended for routine and emergency right-sided colon cancer surgery. This recommendation is based on what appears to be a lower leakage rate, similar survival and lower material cost.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy