SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-264062"
 

Sökning: id:"swepub:oai:DiVA.org:uu-264062" > Hearing and Patient...

Hearing and Patient Satisfaction Among 19 Patients Who Received Implants Intended for Hybrid Hearing : A Two-Year Follow-Up

Erixon, Elsa (författare)
Uppsala universitet,Öron-, näs- och halssjukdomar
Rask-Andersen, Helge (författare)
Uppsala universitet,Öron-, näs- och halssjukdomar
 (creator_code:org_t)
2015
2015
Engelska.
Ingår i: Ear and Hearing. - 0196-0202 .- 1538-4667. ; 36:5, s. E271-E278
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: To measure patient satisfaction and correlate to hearing results in partially deaf patients, after hearing preservation cochlear implant surgery with hybrid hearing strategy, and to evaluate the stability of residual low-frequency hearing (LFH) over time. Design: A patient satisfaction survey and a retrospective, 2-year follow-up journal study. Nineteen partially deaf patients intended for hybrid hearing responded to a questionnaire when they had used their cochlear implants for at least a year. The questionnaire consisted of the International Outcome Inventory for Hearing Aids, EuroQol Group visual analogue scale and nine questions about hybrid hearing. Pure-tone audiometry, monosyllables, and hearing in noise test results from the patients' medical records were evaluated and compared with the results from the patient satisfaction survey. Results: All of the patients were satisfied with their CIs. The mean International Outcome Inventory for Hearing Aids score was 29. The CIs provided a major contribution to the speech comprehension of these partially deaf patients. Two years after surgery, the patients' mean binaural score on tests of monosyllables was 58%, and the mean signal to noise ratio was 4.6 dB. We observed ongoing deteriorations in the residual hearing of the operated ears that surpassed the deteriorations observed in the contralateral ears. One month after surgery, the LFH loss (125-500 Hz) was 17 dB, and after 2 years, this loss was 24 dB compared with 5 dB in the nonoperated ear. There were no significant correlations between preserved LFH and patient satisfaction or speech perception results. Conclusions: Electric stimulation provided a major contribution to speech comprehension of partially deaf patients. The gain reached in speech understanding widely exceeded the downside in losing some residual hearing. All the patients showed a high degree of satisfaction with their CIs regardless of varying hearing preservation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)

Nyckelord

Children
Cochlear implant
EAS
EQ-5D
Hearing preservation
Hybrid hearing
IOI-HA
Partial deafness
Quality of life
Questionnaire
Residual hearing

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Erixon, Elsa
Rask-Andersen, H ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oto rhino laryng ...
Artiklar i publikationen
Ear and Hearing
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy