SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:uu-297776"
 

Search: id:"swepub:oai:DiVA.org:uu-297776" > Comparison of 2D ra...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures

Christersson, Albert (author)
Uppsala universitet,Ortopedi
Nysjö, Johan (author)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion
Berglund, Lars (author)
Uppsala universitet,Uppsala kliniska forskningscentrum (UCR)
show more...
Malmberg, Filip (author)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion,Radiologi
Sintorn, Ida-Maria (author)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion
Nyström, Ingela (author)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion
Larsson, Sune (author)
Uppsala universitet,Ortopedi
show less...
 (creator_code:org_t)
2016-02-27
2016
English.
In: Skeletal Radiology. - : Springer Science and Business Media LLC. - 0364-2348 .- 1432-2161. ; 45:6, s. 763-769
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective The aim of the present study was to compare the reliability and agreement between a computer tomography-based method (CT) and digitalised 2D radiographs (XR) when measuring change in dorsal angulation over time in distal radius fractures. Materials and methods Radiographs from 33 distal radius fractures treated with external fixation were retrospectively analysed. All fractures had been examined using both XR and CT at six times over 6 months postoperatively. The changes in dorsal angulation between the first reference images and the following examinations in every patient were calculated from 133 follow-up measurements by two assessors and repeated at two different time points. The measurements were analysed using Bland-Altman plots, comparing intra- and inter-observer agreement within and between XR and CT. Results The mean differences in intra- and inter-observer measurements for XR, CT, and between XR and CT were close to zero, implying equal validity. The average intra- and inter-observer limits of agreement for XR, CT, and between XR and CT were +/- 4.4 degrees, +/- 1.9 degrees and +/- 6.8 degrees respectively. Conclusions For scientific purpose, the reliability of XR seems unacceptably low when measuring changes in dorsal angulation in distal radius fractures, whereas the reliability for the semi-automatic CT-based method was higher and is therefore preferable when a more precise method is requested.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Keyword

Computerized Image Processing
Datoriserad bildbehandling

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view