SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-305173"
 

Sökning: id:"swepub:oai:DiVA.org:uu-305173" > Comparison of optom...

Comparison of optomagnetic and AC susceptibility readouts in a magnetic nanoparticle agglutination assay for detection of C-reactive protein

Fock, Jeppe (författare)
Technical University of Denmark
Parmvi, Mattias (författare)
Technical University of Denmark;Blusense Diagnost, Box 68,Fruebjergvej 3, DK-2100 Copenhagen O, Denmark
Strömberg, Mattias (författare)
Uppsala universitet,Fasta tillståndets fysik
visa fler...
Svedlindh, Peter (författare)
Uppsala universitet,Fasta tillståndets fysik
Donolato, Marco (författare)
Technical University of Denmark; Blusense Diagnost, Box 68,Fruebjergvej 3, DK-2100 Copenhagen O, Denmark
Fougt Hansen, Mikkel (författare)
Technical University of Denmark
visa färre...
 (creator_code:org_t)
Elsevier, 2017
2017
Engelska.
Ingår i: Biosensors & bioelectronics. - : Elsevier. - 0956-5663 .- 1873-4235. ; 88, s. 94-100
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • There is an increasing need to develop biosensor methods that are highly sensitive and, that can be combined with low-cost consumables. The use of magnetic nanoparticles (MNPs) is attractive because their detection is compatible with low-cost disposables and because application of a magnetic field can be used to accelerate assay kinetics. We present the first study and comparison of the performance of magnetic susceptibility measurements and a newly proposed optomagnetic method. For the comparison we use the C-reactive protein (CRP) induced agglutination of identical samples of 100 nm MNPs conjugated with CRP antibodies. Both methods detect agglutination as a shift to lower frequencies in measurements of the dynamics in response to an applied oscillating magnetic field. The magnetic susceptibility method probes the magnetic response whereas the optomagnetic technique probes the modulation of laser light transmitted through the sample. The two techniques provided highly correlated results upon agglutination when they measure the decrease of the signal from the individual MNPs (turn-off detection strategy), whereas the techniques provided different results, strongly depending on the read-out frequency, when detecting the signal due to MNP agglomerates (turn-on detection strategy). These observations are considered to be caused by differences in the volume-dependence of the magnetic and optical signals from agglomerates. The highest signal from agglomerates was found in the optomagnetic signal at low frequencies.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies (hsv//eng)

Nyckelord

Brownian relaxation
CRP
Agglutination assay
Magnetic beads
Biosensor
Engineering Science with specialization in Solid State Physics
Teknisk fysik med inriktning mot fasta tillståndets fysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy