SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-306609"
 

Sökning: id:"swepub:oai:DiVA.org:uu-306609" > Coherent Diffractiv...

Coherent Diffractive Imaging with X-ray Lasers

Hantke, Max Felix, 1984- (författare)
Uppsala universitet,Molekylär biofysik
Maia, Filipe R. N. C., Dr. (preses)
Uppsala universitet,Molekylär biofysik
Hajdu, Janos, Prof. (preses)
Uppsala universitet,Molekylär biofysik
visa fler...
Svenda, Martin, Dr. (preses)
Uppsala universitet,Molekylär biofysik
Weckert, Edgar, Prof. (opponent)
Hamburg University
visa färre...
 (creator_code:org_t)
ISBN 9789155497484
Uppsala : Acta Universitatis Upsaliensis, 2016
Engelska 84 s.
Serie: Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, 1651-6214 ; 1451
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • The newly emerging technology of X-ray free-electron lasers (XFELs) has the potential to revolutionise molecular imaging. XFELs generate very intense X-ray pulses and predictions suggest that they may be used for structure determination to atomic resolution even for single molecules. XFELs produce femtosecond pulses that outrun processes of radiation damage and permit the study of structures at room temperature and of structural dynamics.While the first demonstrations of flash X-ray diffractive imaging (FXI) on biological particles were encouraging, they also revealed technical challenges. In this work we demonstrated how some of these challenges can be overcome. We exemplified, with heterogeneous cell organelles, how tens of thousands of FXI diffraction patterns can be collected, sorted, and analysed in an automatic data processing pipeline. We improved  image resolution and reduced problems with missing data. We validated, described, and deposited the experimental data in the Coherent X-ray Imaging Data Bank.We demonstrated that aerosol injection can be used to collect FXI data at high hit ratios and with low background. We reduced problems with non-volatile sample contaminants by decreasing aerosol droplet sizes from ~1000 nm to ~150 nm. We achieved this by adapting an electrospray aerosoliser to the Uppsala sample injector. Mie scattering imaging was used as a diagnostic tool to measure positions, sizes, and velocities of individual injected particles.XFEL experiments generate large amounts of data at high rates. Preparation, execution, and data analysis of these experiments benefits from specialised software. In this work we present new open-source software tools that facilitates prediction, online-monitoring, display, and pre-processing of XFEL diffraction data.We hope that this work is a valuable contribution in the quest of transitioning FXI from its first experimental demonstration into a technique that fulfills its potentials.

Ämnesord

NATURVETENSKAP  -- Biologi -- Biofysik (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biophysics (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)
NATURVETENSKAP  -- Biologi -- Strukturbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Structural Biology (hsv//eng)

Nyckelord

coherent diffractive X-ray imaging
lensless imaging
coherent X-ray diffractive imaging
flash diffractive imaging
single particle imaging
aerosol injection
electrospray injection
substrate-free sample delivery
carboxysome
phase retrieval
X-ray diffraction software
X-ray free-electron laser
XFEL
FEL
CXI
CDI
CXDI
FXI

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy