SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-317287"
 

Sökning: id:"swepub:oai:DiVA.org:uu-317287" > The Anatomical Basi...

The Anatomical Basis of the Lumbar Artery PerforatorFlap : A Cadaveric and Computer Tomography AngiogramStudy

Calì-Cassi, Lorenzo (författare)
Uppsala universitet,Plastikkirurgi
Rozen, Shai M. (författare)
Mani, Maria (författare)
Uppsala universitet,Plastikkirurgi
visa fler...
Thorir, Audolfsson (författare)
Uppsala universitet,Plastikkirurgi
Gangadasu, Reddy (författare)
Rodríguez-Lorenzo, Andrés (författare)
Uppsala universitet,Plastikkirurgi
visa färre...
 (creator_code:org_t)
Remedy Publications LLC, 2016
2016
Engelska.
Ingår i: Clinics in Surgery Journal. - : Remedy Publications LLC. - 2474-1647. ; 1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Lumbar skin flaps based on cutaneous perforators arising from the lumbar artery have been described for coverage of lumbosacral defects and as free flaps for autologous breast reconstruction. Thus, the purpose of this study is to clarify anatomical aspects of the lumbar artery perforator flaps pertaining improvement in utility and design of this flap. Methods: Five fresh human bodies were dissected and twenty three-dimensional computed tomographic (CT) angiographic previously used for the evaluation of the deep inferior epigastric perforator flap in patients that underwent breast reconstruction were evaluated. All cutaneous lumbar artery perforators were analyzed for total number, location, and external diameter. Results: The number of perforators observed per side was 1.6±0.84 in the CT angiography and 3±1.05 in the cadaver study. Data from CT angiographies showed a mean diameter of the pedicle of 2.76±0.74 mm. This perforators were located at the mean distance from the midline (spinal process) of 76.56±6.97 mm, the mean length pedicle were 19.88±7.57 mm. Data from the cadaveric dissection study the mean diameter of the pedicle were 1.96±0.57 mm, the mean distance from the midline were 69.6±22.5 mm. Conclusion: The lumbar artery perforator flap is based on a perforator that has a predictable location and presents a good caliber. Versatility of design of a pedicled flap as a propeller, bilobed or transposition flap based on this reliable perforator can be useful to reconstruct complex defects in the lumbar area. Preoperative planning with CT angiography is recommended to assess the location and caliber of the perforator allowing a better design of the flap

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy