SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-320707"
 

Sökning: id:"swepub:oai:DiVA.org:uu-320707" > Collapsed cone dose...

Collapsed cone dose calculations for heterogeneous tissues in brachytherapy using primary and scatter separation source data

Ahnesjö, Anders, 1953- (författare)
Uppsala universitet,Medicinsk strålningsvetenskap,Uppsala University, Sweden
van Veelen, Bob (författare)
Elekta Brachytherapy, NL-3905 TH Veenendaal, Netherlands.
Carlsson Tedgren, Åsa (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Region Östergötland, Radiofysikavdelningen US,Karolinska University Hospital, Sweden
 (creator_code:org_t)
ELSEVIER IRELAND LTD, 2017
2017
Engelska.
Ingår i: Computer Methods and Programs in Biomedicine. - : ELSEVIER IRELAND LTD. - 0169-2607 .- 1872-7565. ; 139, s. 17-29
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and Objective: Brachytherapy is a form of radiation therapy using sealed radiation sources inserted within or in the vicinity of the tumor of, e.g., gynecological, prostate or head and neck cancers. Accurate dose calculation is a crucial part of the treatment planning. Several reviews have called for clinical software with model-based algorithms that better take into account the effects of patient individual distribution of tissues, source-channel and shielding attenuation than the commonly employed TG-43 formalism which simply map homogeneous water dose distributions onto the patient. In this paper we give a comprehensive and thorough derivation of such an algorithm based on collapsed cone point-kernel superposition, and describe details of its implementation into a commercial treatment planning system for clinical use. Methods: A brachytherapy version of the collapsed-cone algorithm using analytical raytraces of the primary photon radiation followed by successive scattering dose calculation for once and multiply scattered photons is described in detail, including derivation of the corresponding set of recursive equations for energy transport along cone axes/transport lines and the coupling to clinical source modeling. Specific implementation issues for setting up of the calculation grid, handling of intravoxel gradients and voxels partly containing non patient applicator material are given. Results: Sample runs for two clinical cases are shown, one being a gynecological application with a tungsten-shielded applicator and one a breast implant. These two cases demonstrate the impact of improved dose calculation versus TG-43 formalism. Conclusions: Use of model-based dose calculation algorithms for brachytherapy taking the three-dimensional treatment geometry into account increases the dosimetric accuracy in planning and follow up of treatments. The comprehensive description and derivations provided gives a rigid background for further clinical, educational and research applications.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Brachytherapy
Radiotherapy treatment planning
Model-based dose calculation
Advanced collapsed cone engine
Point kernel superposition

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy