Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET

van der Vos, Charlotte S (författare)
Koopman, Daniëlle (författare)
Rijnsdorp, Sjoerd (författare)
visa fler...
Arends, Albert J (författare)
Boellaard, Ronald (författare)
van Dalen, Jorn A (författare)
Lubberink, Mark (författare)
Uppsala universitet,Radiologi
Willemsen, Antoon T M (författare)
Visser, Eric P (författare)
visa färre...
 (creator_code:org_t)
2017-07-08
2017
Engelska.
Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 44:Suppl 1, s. S4-S16
  • Forskningsöversikt (refereegranskat)
Abstract Ämnesord
Stäng  
  • In recent years, there have been multiple advances in positron emission tomography/computed tomography (PET/CT) that improve cancer imaging. The present generation of PET/CT scanners introduces new hardware, software, and acquisition methods. This review describes these new developments, which include time-of-flight (TOF), point-spread-function (PSF), maximum-a-posteriori (MAP) based reconstruction, smaller voxels, respiratory gating, metal artefact reduction, and administration of quadratic weight-dependent (18)F-fluorodeoxyglucose (FDG) activity. Also, hardware developments such as continuous bed motion (CBM), (digital) solid-state photodetectors and combined PET and magnetic resonance (MR) systems are explained. These novel techniques have a significant impact on cancer imaging, as they result in better image quality, improved small lesion detectability, and more accurate quantification of radiopharmaceutical uptake. This influences cancer diagnosis and staging, as well as therapy response monitoring and radiotherapy planning. Finally, the possible impact of these developments on the European Association of Nuclear Medicine (EANM) guidelines and EANM Research Ltd. (EARL) accreditation for FDG-PET/CT tumor imaging is discussed.

Nyckelord

Digital PET
EARL
Lesion detectability
PET/MR
Point-spread-function
Time-of-flight

Publikations- och innehållstyp

ref (ämneskategori)
for (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy