SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-329206"
 

Sökning: id:"swepub:oai:DiVA.org:uu-329206" > Protective ventilat...

Protective ventilation reduces Pseudomonas aeruginosa growth in lung tissue in a porcine pneumonia model

Sperber, Jesper (författare)
Uppsala universitet,Centrum för klinisk forskning i Sörmland (CKFD),Centre for Clinical Research Sörmland, Department of Anesthesiology & Intensive Care Mälarsjukhuset, SE-631 88, Eskilstuna, Sweden
Nyberg, Axel (författare)
Uppsala universitet,Centrum för klinisk forskning i Sörmland (CKFD),Centre for Clinical Research Sörmland, Department of Anesthesiology & Intensive Care Mälarsjukhuset, SE-631 88, Eskilstuna, Sweden
Lipcsey, Miklós (författare)
Uppsala universitet,Hedenstiernalaboratoriet,Anestesiologi och intensivvård
visa fler...
Melhus, Åsa (författare)
Uppsala universitet,Klinisk mikrobiologi
Larsson, Anders (författare)
Uppsala universitet,Biokemisk struktur och funktion,Klinisk kemi
Sjölin, Jan (författare)
Uppsala universitet,Infektionssjukdomar,Infektionsmedicin
Castegren, Markus, 1976- (författare)
Karolinska Institutet,Uppsala universitet,Centrum för klinisk forskning i Sörmland (CKFD),Hedenstiernalaboratoriet,Anestesiologi och intensivvård,Perioperative Medicine and Intensive Care, Karolinska University Hospital and CLINTEC, Karolinska Institute, Stockholm, Sweden
visa färre...
 (creator_code:org_t)
2017-08-31
2017
Engelska.
Ingår i: Intensive & Critical Care Nursing. - : Springer Science and Business Media LLC. - 0964-3397 .- 1532-4036. ; 5
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Mechanical ventilation with positive end expiratory pressure and low tidal volume, i.e. protective ventilation, is recommended in patients with acute respiratory distress syndrome. However, the effect of protective ventilation on bacterial growth during early pneumonia in non-injured lungs is not extensively studied. The main objectives were to compare two different ventilator settings on Pseudomonas aeruginosa growth in lung tissue and the development of lung injury.METHODS: A porcine model of severe pneumonia was used. The protective group (n = 10) had an end expiratory pressure of 10 cm H2O and a tidal volume of 6 ml x kg-1. The control group (n = 10) had an end expiratory pressure of 5 cm H2O and a tidal volume of 10 ml x kg-1. 1011 colony forming units of Pseudomonas aeruginosa were inoculated intra-tracheally at baseline, after which the experiment continued for 6 h. Two animals from each group received only saline, and served as sham animals. Lung tissue samples from each animal were used for bacterial cultures and wet-to-dry weight ratio measurements.RESULTS: The protective group displayed lower numbers of Pseudomonas aeruginosa (p < 0.05) in the lung tissue, and a lower wet-to-dry ratio (p < 0.01) than the control group. The control group deteriorated in arterial oxygen tension/inspired oxygen fraction, whereas the protective group was unchanged (p < 0.01).CONCLUSIONS: In early phase pneumonia, protective ventilation with lower tidal volume and higher end expiratory pressure has the potential to reduce the pulmonary bacterial burden and the development of lung injury.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Nyckelord

Bacterial infections
Critical care
Models
animal
Protective ventilation
Ventilators
mechanical
Infectious Diseases

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy