A method of manufacturing microfluidic contact lenses by using irreversible bonding and thermoforming

An, Hongbin (författare)
Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Hubei, Peoples R China
Chen, Liangzhou (författare)
Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Hubei, Peoples R China
Liu, Xiaojun (författare)
Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Hubei, Peoples R China
visa fler...
Zhao, Bin (författare)
Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Hubei, Peoples R China
Ma, Donglin (författare)
Huazhong Univ Sci & Technol, Sch Opt & Elect Informat, Wuhan 430074, Hubei, Peoples R China
Wu, Zhigang, 1977- (författare)
Uppsala universitet,Mikrosystemteknik,Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Hubei, Peoples R China
visa färre...
 (creator_code:org_t)
2018-07-11
2018
Engelska.
Ingår i: Journal of Micromechanics and Microengineering. - : IOP PUBLISHING LTD. - 0960-1317 .- 1361-6439. ; 28:10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this paper, we present the development of microfluidic contact lenses, which is based on the advantages of wearable microfluidics and can have great potential in the ophthalmology healthcare field. The development consists of two parts; the manufacturing process and the usability tests of the devices. In the manufacturing process, we firstly extended silane coupling and surface modification to irreversibly bond plastic membranes with microchannel-molded silicone rubber, to form the plastic-PDMS plane assemblies, and then molded the plane into a contact lens by thermoforming. We systematically investigated the effects of thermoforming factors, heating temperatures and the terrace die's sphere radius on channels by using the factorial experiment design. In addition, various tests were conducted to verify the usability of the devices. Through blockage and leakage tests, the devices were proved to be feasible, with no channel-blockages and could stand high pressures. Through a wearing test, the contact lenses were confirmed to be harmless on the living body. Furthermore, by performing the manipulating test, the device was proved to be liquid-controllable. These works provide a foundation for the applications of microfluidic contact lenses in ophthalmology.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

microfluidic contact lenses
thermoforming
factorial experiment
contact lens

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy