SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-368888"
 

Sökning: id:"swepub:oai:DiVA.org:uu-368888" > Test-retest reliabi...

Test-retest reliability of new and conventional echocardiographic parameters of left ventricular systolic function

Baron, Tomasz (författare)
Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),Kardiologi,Klinisk fysiologi
Berglund, Lars, 1955- (författare)
Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),Geriatrik
Hedin, Eva-Maria (författare)
Uppsala universitet,Kardiologi-arrytmi
visa fler...
Flachskampf, Frank, 1957- (författare)
Uppsala universitet,Klinisk fysiologi,Kardiologi
visa färre...
 (creator_code:org_t)
2018-10-27
2019
Engelska.
Ingår i: Clinical Research in Cardiology. - : Springer Science and Business Media LLC. - 1861-0684 .- 1861-0692. ; 108:4, s. 355-365
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Reliability of left ventricular function measurements depends on actual biological conditions, repeated registrations and their analyses.Objective: To investigate test–retest reliability of speckle-tracking-derived strain measurements and its determinants compared to the conventional parameters, such as ejection fraction (EF), LV volumes and mitral annular plane systolic excursion (MAPSE).Methods: In 30 patients with a wide range of left ventricular function (mean EF 46.4 ± 16.4%, range 14–73%), standard echo views were acquired independently in a blinded fashion by two different echocardiographers in immediate sequence and analyzed off-line by two independent readers, creating 4 data sets per patient. Test–retest reliability of studied parameters was calculated using the smallest detectable change (SDC) and a total, inter-acquisition and inter-reader intra-class correlation coefficient (ICC).Results: The smallest detectable change normalized to the mean absolute value of the measured parameter (SDCrel) was lowest for MAPSE (10.7%). SDCrel for EF was similar to GLS (14.2 and 14.7%, respectively), while SDCrel for CS was much higher (35.6%). The intra-class correlation coefficient was excellent (> 0.9) for all measures of the left ventricular function. Intra-patient inter-acquisition reliability (ICCacq) was significantly better than inter-reader reliability (ICCread) (0.984 vs. 0.950, p = 0.03) only for EF, while no significant difference was observed for any other LV function parameter. Mean intra-subject standard deviations were significantly correlated to the mean values for CS and LV volumes, but not for the other studied parameters.Conclusions: In a test–retest setting, both with normal and impaired left ventricular function, the smallest relative detectable change of EF, GLS and MAPSE was similar (11–15%), but was much higher for CS (35%). Surprisingly, reliability of GLS was not superior to that of EF. Acquisition and reader to a similar extent influenced the reliability of measurements of all left ventricular function measures except for ejection fraction, where the reliability was more dependent on the reader than on the acquisition.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Ejection fraction
Global longitudinal strain
Left ventricular function
Mitral annulus plane systolic excursion
Test–retest reliability
Cardiology
Kardiologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Baron, Tomasz
Berglund, Lars, ...
Hedin, Eva-Maria
Flachskampf, Fra ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Clinical Researc ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy