Sökning: id:"swepub:oai:DiVA.org:uu-369751" >
The neutron camera ...
The neutron camera upgrade for MAST Upgrade
-
- Cecconello, Marco (författare)
- Uppsala universitet,Tillämpad kärnfysik,EURATOM VR Assoc, Uppsala, Sweden
-
- Sperduti, Andrea (författare)
- Uppsala universitet,Tillämpad kärnfysik,EURATOM VR Assoc, Uppsala, Sweden
-
- Fitzgerald, I. (författare)
- Culham Sci Ctr, EURATOM CCFE Fus Assoc, Abingdon, Oxon, England
-
visa fler...
-
- Conroy, Sean (författare)
- Uppsala universitet,Tillämpad kärnfysik,EURATOM VR Assoc, Uppsala, Sweden
-
- Holm, Stefan Jarl (författare)
- Uppsala universitet,Tillämpad kärnfysik,EURATOM VR Assoc, Uppsala, Sweden
-
- Weiszflog, Matthias (författare)
- Uppsala universitet,Tillämpad kärnfysik,EURATOM VR Assoc, Uppsala, Sweden
-
visa färre...
-
(creator_code:org_t)
- AMER INST PHYSICS, 2018
- 2018
- Engelska.
-
Ingår i: Review of Scientific Instruments. - : AMER INST PHYSICS. - 0034-6748 .- 1089-7623. ; 89:10
- Relaterad länk:
-
https://www.osti.gov...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted. In addition, the results from the characterization and performance studies of the neutron detectors using standard gamma-rays sources and a Cf-252 source are discussed. The proposed design has a time resolution of 1 ms with a statistical uncertainty of less than 10% for all MAST Upgrade scenarios with a spatial resolution of 10 cm: higher spatial resolution is possible by moving the LoSs in-between plasma discharges. The energy resolution of the neutron detector is better than 10% for a light output of 0.8 MeVee, and the measured pulse shape discrimination is satisfactory.
Ämnesord
- NATURVETENSKAP -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)