SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-382933"
 

Sökning: id:"swepub:oai:DiVA.org:uu-382933" > Separation of water...

Separation of water and fat signal in whole-body gradient echo scans using convolutional neural networks

Andersson, Jonathan (författare)
Uppsala universitet,Radiologi
Ahlström, Håkan, 1953- (författare)
Uppsala universitet,Radiologi,Antaros Med, Mölndal, Sweden
Kullberg, Joel, 1979- (författare)
Uppsala universitet,Radiologi,Antaros Med, Mölndal, Sweden
 (creator_code:org_t)
2019-04-29
2019
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 82:3, s. 1177-1186
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To perform and evaluate water–fat signal separation of whole‐body gradient echo scans using convolutional neural networks.Methods: Whole‐body gradient echo scans of 240 subjects, each consisting of 5 bipolar echoes, were used. Reference fat fraction maps were created using a conventional method. Convolutional neural networks, more specifically 2D U‐nets, were trained using 5‐fold cross‐validation with 1 or several echoes as input, using the squared difference between the output and the reference fat fraction maps as the loss function. The outputs of the networks were assessed by the loss function, measured liver fat fractions, and visually. Training was performed using a graphics processing unit (GPU). Inference was performed using the GPU as well as a central processing unit (CPU).Results: The loss curves indicated convergence, and the final loss of the validation data decreased when using more echoes as input. The liver fat fractions could be estimated using only 1 echo, but results were improved by use of more echoes. Visual assessment found the quality of the outputs of the networks to be similar to the reference even when using only 1 echo, with slight improvements when using more echoes. Training a network took at most 28.6 h. Inference time of a whole‐body scan took at most 3.7 s using the GPU and 5.8 min using the CPU.Conclusion: It is possible to perform water–fat signal separation of whole‐body gradient echo scans using convolutional neural networks. Separation was possible using only 1 echo, although using more echoes improved the results.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Dixon
convolutional neural network
deep learning
magnetic resonance imaging
neural network
water-fat separation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Andersson, Jonat ...
Ahlström, Håkan, ...
Kullberg, Joel, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy