SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-390964"
 

Sökning: id:"swepub:oai:DiVA.org:uu-390964" > MRI detection of ce...

MRI detection of cerebral microbleeds : size matters

Haller, Sven (författare)
Uppsala universitet,Radiologi,Faculty of Medicine, University of Geneva
Scheffler, Max (författare)
Salomir, Rares (författare)
visa fler...
Herrmann, François R. (författare)
Gold, Gabriel (författare)
Montandon, Marie-Louise (författare)
Kövari, Enikö (författare)
visa färre...
 (creator_code:org_t)
2019-08-08
2019
Engelska.
Ingår i: Neuroradiology. - : Springer Science and Business Media LLC. - 0028-3940 .- 1432-1920. ; 61:10, s. 1209-1213
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: Cerebral microbleeds (CMB) play an important role as an imaging biomarker notably in vascular and neurodegenerative diseases. Current clinical brain MRI underestimates the number of CMB with respect to histopathology. It is expected that small CMBs are more likely to be false-negatives, yet this has not been demonstrated and the average size of false-negative and true-positive CMBs have not been established.METHODS: The radiologic-histopathologic correlation study was approved by the local review board and included 42 consecutive cases (mean age at death, 80.7 ± 10.0 years; 23 females and 19 men) between 12 January 2012 and 10 December 2012 having undergone brain autopsy. Postmortem SWI (susceptibility-weighted imaging) images were acquired on a clinical 3T system using parameters similar to clinical routine. The detection of CMB on postmortem MRI was compared with corresponding histopathological slices.RESULTS: Postmortem MRI detected 23 true-positive CMB. Histopathology additionally detected 68 CMBs (false-negative MRI CMBs). The average size true-positive MRI CMBs had on histopathology was 3.6 ± 7.1 mm3. The average size false-negative MRI CMBs was significantly smaller (p < 0.05), measuring 0.3 ± 1.2 mm3 on histopathology.CONCLUSION: Size matters. As expected, the average size of true-positive MRI CMB was around 10 times larger as compared with false-negative MRI CMB. Evidently, in addition to size, other factors will influence the detectability of CMB, including iron content, ratio of Fe2+/Fe3+, spatial configuration, and location, yet this remains to be elucidated in future studies.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Dementia
MRI
Microbleeds
Pathology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy