SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-400854"
 

Sökning: id:"swepub:oai:DiVA.org:uu-400854" > Accuracy of PET Par...

Accuracy of PET Partial Volume Correction in Tracer Uptake Measurements with Six Isotopes

Hamill, James J. (författare)
Siemens Med Solut, Knoxville, TN 37932 USA
Sjöholm, Therese (författare)
Uppsala universitet,Radiologi,A STAR NUS Clin Imaging Res Ctr, Singapore, Singapore
Townsend, David (författare)
A STAR NUS Clin Imaging Res Ctr, Singapore, Singapore
visa fler...
Conti, Maurizio (författare)
Siemens Med Solut, Knoxville, TN 37932 USA
visa färre...
 (creator_code:org_t)
2016
2016
Engelska.
Ingår i: 2016 Ieee Nuclear Science Symposium, Medical Imaging Conference And Room-Temperature Semiconductor Detector Workshop (Nss/Mic/Rtsd). - 9781509016426 - 9781509016433
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Soderlund et al recently published a sphere phantom study with six PET tracers, concluding that image quality was good but tracer concentration measurements based on mean uptake (MEAN) were strongly affected by partial volume errors (PVE). In this work we ask if a previously published PVE correction method (CORR, described in 2002 by Hickeson and colleagues) is more accurate. The CORR method may be appropriate in applications like lung-nodule PET/CT when isolated hot structures, perhaps lung nodules, sit in a region of approximately uniform background, and the object's volume (V) is known from CT. A volume of interest in the PET image (VOI) is defined around the object. Background is estimated from voids adjacent to the VOI. Tracer concentration in Bq/ml is set to the background-corrected VOI total, divided by V. Hot spheres had diameters 10, 13, 17 and 22 mm. Cold spheres had diameters 28 and 37 mm. The phantom was filled with positron-emitting F-18, C-11, Zr-89, I-124, Ga-68 and Y-90 activity with a sphere to background ratio of approximately 4:1. TOF PET data from a Siemens mCT PET/CT scanner were reconstructed with the TOF-PSF method. Using the MEAN and CORR methods, we calculated contrast recovery (CR), defined by NEMA NU 2-2007, for hot and cold spheres. In hot spheres 13 mm or more in diameter, CR based on CORR was between 90% and 10.5% for, all but one measurement with F-18, C-11, Zr-89, I-124 Ga-68. In the 10 mm sphere, CR was 82% on average. In these spheres and these isotopes, CR based on MEAN varied between 0.3 and 0.8. In the cold spheres, recovery based on CORR was between 0.7 and 1.0 for these isotopes. Reconstructions of Y-90 were less accurate. In conclusion, CORR improved contrast recovery measurements, compared to MEAN.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hamill, James J.
Sjöholm, Therese
Townsend, David
Conti, Maurizio
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
2016 Ieee Nuclea ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy