Evaluation of Arterial Spin Labeling MRI : Comparison with 15O-Water PET on an Integrated PET/MR Scanner
-
- Fahlström, Markus (författare)
- Uppsala universitet,Radiologi
-
- Appel, Lieuwe (författare)
- Uppsala universitet,Radiologi
-
- Kumlien, Eva (författare)
- Uppsala universitet,Landtblom: Neurovetenskap
-
visa fler...
-
- Danfors, Torsten, 1964- (författare)
- Uppsala universitet,Radiologi
-
- Engström, Mathias (författare)
- GE Healthcare, Applied Science Laboratory
-
- Wikström, Johan, 1964- (författare)
- Uppsala universitet,Radiologi
-
- Antoni, Gunnar (författare)
- Uppsala universitet,Preparativ läkemedelskemi
-
- Larsson, Elna-Marie (författare)
- Uppsala universitet,Radiologi
-
- Lubberink, Mark (författare)
- Uppsala universitet,Radiologi
-
visa färre...
-
(creator_code:org_t)
- 2021-05-01
- 2021
- Engelska.
-
Ingår i: Diagnostics (Basel). - : MDPI. - 2075-4418. ; 11:5
- Relaterad länk:
-
https://doi.org/10.3...
-
visa fler...
-
https://uu.diva-port... (primary) (Raw object)
-
https://www.mdpi.com...
-
https://urn.kb.se/re...
-
https://doi.org/10.3...
-
visa färre...
Abstract
Ämnesord
Stäng
- Cerebral blood flow (CBF) measurements are of high clinical value and can be acquired non-invasively with no radiation exposure using pseudo-continuous arterial spin labeling (ASL). The aim of this study was to evaluate accordance in resting state CBF between ASL (CBFASL) and 15O-water positron emission tomography (PET) (CBFPET) acquired simultaneously on an integrated 3T PET/MR system. The data comprised ASL and dynamic 15O-water PET data with arterial blood sampling of eighteen subjects (eight patients with focal epilepsy and ten healthy controls, age 21 to 61 years). 15O-water PET parametric CBF images were generated using a basis function implementation of the single tissue compartment model. Cortical and subcortical regions were automatically segmented using Freesurfer. Average CBFASL and CBFPET in grey matter were 60 ± 20 and 75 ± 22 mL/100 g/min respectively, with a relatively high correlation (r = 0.78, p < 0.001). Bland-Altman analysis revealed poor agreement (bias = −15 mL/100 g/min, lower and upper limits of agreements = −16 and 45 mL/100 g/min, respectively) with a negative relationship. Accounting for the negative relationship, the width of the limits of agreement could be narrowed from 61 mL/100 g/min to 35 mL/100 g/min using regression-based limits of agreements. Although a high correlation between CBFASL and CBFPET was found, the agreement in absolute CBF values was not sufficient for ASL to be used interchangeably with 15O-water PET.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- ASL
- CBF
- PET/MR
- validation
- 15O-water
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Fahlström, Marku ...
-
Appel, Lieuwe
-
Kumlien, Eva
-
Danfors, Torsten ...
-
Engström, Mathia ...
-
Wikström, Johan, ...
-
visa fler...
-
Antoni, Gunnar
-
Larsson, Elna-Ma ...
-
Lubberink, Mark
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
Diagnostics (Bas ...
- Av lärosätet
-
Uppsala universitet