SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-406209"
 

Sökning: id:"swepub:oai:DiVA.org:uu-406209" > Evaluation of Artif...

Evaluation of Artificial Fixation of the Incus and Malleus With Minimally Invasive Intraoperative Laser Vibrometry (MIVIB) in a Temporal Bone Model

Gladine, Kilian (författare)
Univ Antwerp, Lab Biomed Phys, Antwerp, Belgium
Wales, Jeremy (författare)
Karolinska Institutet
Silvola, Juha (författare)
Akershus Univ Hosp, Dept Otorhinolaryngol, Oslo, Norway;Univ Oslo, Oslo, Norway
visa fler...
Muyshondt, Pieter G. G. (författare)
Univ Antwerp, Lab Biomed Phys, Antwerp, Belgium
Topsakal, Vedat (författare)
Univ Antwerp, Antwerp Univ Hosp, Dept Otorhinolaryngol & Head & Neck Surg, Antwerp, Belgium
De Heyning, Paul Van (författare)
Univ Antwerp, Antwerp Univ Hosp, Dept Otorhinolaryngol & Head & Neck Surg, Antwerp, Belgium
Dirckx, Joris J. J. (författare)
Univ Antwerp, Lab Biomed Phys, Antwerp, Belgium
von Unge, Magnus (författare)
Uppsala universitet,Centrum för klinisk forskning, Västerås,Akershus Univ Hosp, Dept Otorhinolaryngol, Oslo, Norway;Univ Oslo, Oslo, Norway
visa färre...
 (creator_code:org_t)
LIPPINCOTT WILLIAMS & WILKINS, 2020
2020
Engelska.
Ingår i: Otology and Neurotology. - : LIPPINCOTT WILLIAMS & WILKINS. - 1531-7129 .- 1537-4505. ; 41:1, s. 45-51
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: A significant number of adults suffer from conductive hearing loss due to chronic otitis media, otosclerosis, or other pathologies. An objective measurement of ossicular mobility is needed to avoid unnecessarily invasive middle ear surgery and to improve hearing outcomes.Methods: Minimally invasive intraoperative laser vibrometry provides a method that is compatible with middle ear surgery, where the tympanic membrane is elevated. The ossicles were driven by a floating mass transducer and their mobility was measured using a laser Doppler vibrometer. Utilising this method, we assessed both the absolute velocities of the umbo and incus long process as well as the incus-to-umbo velocity ratio during artificial fixation of the incus alone or incus and malleus together.Results: The reduction of absolute velocities was 8 dB greater at the umbo and 17 dB at the incus long process for incus-malleus fixations when compared with incus fixation alone. Incus fixation alone resulted in no change to the incus-to-umbo velocity ratio where incus-malleus fixations reduced this ratio (-11 dB). The change in incus velocity was shown to be the most suitable parameter to distinguish between incus fixation and incus-malleus fixation. When the whole frequency range was analyzed, one could also differentiate these two fixations from previously published stapes fixation, where the higher frequencies were less affected.Conclusion: Minimally invasive intraoperative laser vibrometry provides a promising objective analysis of ossicular mobility that would be useful intraoperatively.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)

Nyckelord

Floating mass transducer
Hearing loss
Laser vibrometry
Objective evaluation
Otitis media

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy