Sökning: id:"swepub:oai:DiVA.org:uu-408533" >
A five-axis paralle...
A five-axis parallel kinematic mirror unit for soft X-ray beamlines at MAX IV
-
- Agåker, Marcus (författare)
- Uppsala University,Lund University,Lunds universitet,Uppsala universitet,Molekyl- och kondenserade materiens fysik,Lund Univ, MAX Lab 4, SE-22100 Lund, Sweden,MAX IV-laboratoriet,MAX IV Laboratory
-
- Mueller, Frieder (författare)
- FMB Feinwerk & Messtech GmbH, Friedrich Woehler Str 2, D-12489 Berlin, Germany,FMB Feinwerk und Messtechnik GmbH
-
- Norsk Jensen, Brian (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
visa fler...
-
- Åhnberg, Karl (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Sjöblom, Peter (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Deiwiks, Jochen (författare)
- FMB Feinwerk & Messtech GmbH, Friedrich Woehler Str 2, D-12489 Berlin, Germany,FMB Feinwerk und Messtechnik GmbH
-
- Henniger, Hans (författare)
- FMB Feinwerk & Messtech GmbH, Friedrich Woehler Str 2, D-12489 Berlin, Germany,FMB Feinwerk und Messtechnik GmbH
-
- Pärna, Rainer (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory,University of Tartu
-
- Knudsen, Jan (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Thiagarajan, Balasubramanian (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Såthe, Conny (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
visa färre...
-
(creator_code:org_t)
- INT UNION CRYSTALLOGRAPHY, 2020
- 2020
- Engelska.
-
Ingår i: Journal of Synchrotron Radiation. - : INT UNION CRYSTALLOGRAPHY. - 0909-0495 .- 1600-5775. ; 27, s. 262-271
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://uu.diva-port... (primary) (Raw object)
-
http://dx.doi.org/10... (free)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- With the introduction of the multi-bend achromats in the new fourth-generation storage rings the emittance has decreased by an order of magnitude resulting in increased brightness. However, the higher brightness comes with smaller beam sizes and narrower radiation cones. As a consequence, the requirements on mechanical stability regarding the beamline components increases. Here an innovative five-axis parallel kinematic mirror unit for use with soft X-ray beamlines using off-axis grazing-incidence optics is presented. Using simulations and measurements from the HIPPIE beamline at the MAX IV Laboratory it is shown that it has no Eigen frequencies below 90 Hz. Its positioning accuracy is better than 25 nm linearly and 17-35 mu rad angularly depending on the mirror chamber dimensions.
Ämnesord
- NATURVETENSKAP -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)
Nyckelord
- beamline component
- optics kinematics
- soft X-ray
- MAX IV
- beamline component
- MAX IV
- optics kinematics
- soft X-ray
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Agåker, Marcus
-
Mueller, Frieder
-
Norsk Jensen, Br ...
-
Åhnberg, Karl
-
Sjöblom, Peter
-
Deiwiks, Jochen
-
visa fler...
-
Henniger, Hans
-
Pärna, Rainer
-
Knudsen, Jan
-
Thiagarajan, Bal ...
-
Såthe, Conny
-
visa färre...
- Om ämnet
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Fysik
-
och Acceleratorfysik ...
- Artiklar i publikationen
-
Journal of Synch ...
- Av lärosätet
-
Uppsala universitet
-
Lunds universitet