SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-409836"
 

Sökning: id:"swepub:oai:DiVA.org:uu-409836" > Time-Frequency and ...

Time-Frequency and Energy Correlations of the Transient Voltages Triggered by Cloud to Cloud Discharges

Sapumanage, Nilantha (författare)
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka.
Nanayakkara, Sankha (författare)
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka.
Abegunawardana, Sidath (författare)
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka.
visa fler...
Fernando, Mahendra (författare)
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka.
Cooray, Vernon, 1952- (författare)
Uppsala universitet,Elektricitetslära
visa färre...
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka Elektricitetslära (creator_code:org_t)
Institute of Electrical and Electronics Engineers (IEEE), 2019
2019
Engelska.
Ingår i: IEEE transactions on electromagnetic compatibility (Print). - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9375 .- 1558-187X. ; 61:6, s. 1782-1792
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper presents a study performed on time, frequency, and energy correlations of transient voltages generated by the cloud to cloud discharges. It revealed that the energy embedded in transient voltages have been lumped over few segments of time domain voltage profile than uniquely scattering over the time span. The study further determined that the energy concentration becomes higher in and around the vicinity of the time domain voltage maxima or minima, and such high energy-concentrated segments confined to a minute time span in comparison to the total time span of the transient voltage. The study also established that there is a small time lead or lag between the time domain voltage maxima or minima and the time of energy maximize. Moreover, the analysis deduced that the time lead or time lag phenomenon, is not sensitive to the orientation of the time domain voltage profile, but fuelled by the pulse type. The response time of surge protective devices can become crucial if the stipulated clamping voltages of the protection devices fall close to local peaks of the transient voltages.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Bipolar
cloud to cloud
induced voltage
pulse-burst
spectrogram
SPD
unipolar
wavelet transform

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy