SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-421268"
 

Sökning: id:"swepub:oai:DiVA.org:uu-421268" > Automated GMP-Compl...

Automated GMP-Compliant Production of [Ga-68]Ga-DO3A-Tuna-2 for PET Microdosing Studies of the Glucagon Receptor in Humans

Wagner, Michael, 1957- (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper,Sanofi, Integrated Drug Discovery, R&D Res Platform, D-65929 Frankfurt, Germany.
Doverfjord, Johan G. (författare)
Uppsala universitet,Translationell avbildning med PET
Tillner, Joachim (författare)
Sanofi, Translat Med, D-65929 Frankfurt, Germany.
visa fler...
Antoni, Gunnar (författare)
Uppsala universitet,Institutionen för läkemedelskemi
Haack, Torsten (författare)
Sanofi, Integrated Drug Discovery, R&D Res Platform, D-65929 Frankfurt, Germany.
Bossart, Martin (författare)
Sanofi, Integrated Drug Discovery, R&D Res Platform, D-65929 Frankfurt, Germany.
Laitinen, Iina (författare)
Sanofi, Global Imaging, D-65929 Frankfurt, Germany.
Johansson, Lars (författare)
Antaros Med AB, S-43183 Mölndal, Sweden.
Pierrou, Stefan (författare)
Antaros Med AB, S-43183 Mölndal, Sweden.
Eriksson, Olof (författare)
Antaros Med AB, S-43183 Mölndal, Sweden.;Uppsala Univ, Dept Med Chem, Sci Life Lab, S-75123 Uppsala, Sweden.
Velikyan, Irina, 1966- (författare)
Uppsala universitet,Institutionen för läkemedelskemi,Science for Life Laboratory, SciLifeLab
visa färre...
 (creator_code:org_t)
2020-07-31
2020
Engelska.
Ingår i: Pharmaceuticals. - : MDPI. - 1424-8247. ; 13:8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction: [Ga-68]Ga-DO3A-VS-Cys(40)-Tuna-2 (previously published as [Ga-68]Ga-DO3A-VS-Cys(40)-S01-GCG) has shown high-affinity specific binding to the glucagon receptor (GCGR) in vitro and in vivo in rats and non-human primates in our previous studies, confirming the suitability of the tracer for drug development applications in humans. The manufacturing process of [Ga-68]Ga-DO3A-VS-Cys(40)-Tuna-2 was automated for clinical use to meet the radiation safety and good manufacturing practice (GMP) requirements.Methods:The automated synthesis platform (Modular-Lab PharmTrace, Eckert & Ziegler, Eurotope, Germany), disposable cassettes for(68)Ga-labeling, and pharmaceutical-grade(68)Ge/Ga-68 generator (GalliaPharm(R)) used in the study were purchased from Eckert & Ziegler. The parameters such as time, temperature, precursor concentration, radical scavenger, buffer concentration, and pH, as well as product purification step, were investigated and optimized. Process optimization was conducted with regard to product quality and quantity, as well as process reproducibility. The active pharmaceutical ingredient starting material DO3A-VS-Cys(40)-Tuna-2 (GMP-grade) was provided by Sanofi Aventis.Results:The reproducible and GMP-compliant automated production of [Ga-68]Ga-DO3A-VS-Cys(40)-Tuna-2 with on-line documentation was developed. The non-decay-corrected radiochemical yield was 45.2 +/- 2.5% (n= 3, process validation) at the end of the synthesis with a labeling synthesis duration of 38 min and a quality controlincluding release procedure of 20 min. The radiochemical purity of the product was 98.9 +/- 0.6% (n= 17) with the total amount of the peptide in the preparation of 48 +/- 2 mu g (n= 3, process validation). Radionuclidic purity, sterility, endotoxin content, residual solvent content, and sterile filter integrity tests met the acceptance criteria. The product was stable at ambient temperature for at least 2 h.Conclusion:The fully automated GMP-compliant manufacturing process was developed and thoroughly validated. The resulting [Ga-68]Ga-DO3A-VS-Cys(40)-Tuna-2 was used in a clinical study for accurate quantification of GCGR occupancy by a dual anti-diabetic drug in vivo in humans.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

glucagon receptor
diabetes
GMP
Gallium-68
automation
radiopharmaceuticals

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy